EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Sources of harmonic distortion in consumer power supply circuits and their impact on power quality in low-voltage smart grids

Tomasz Korbiel

Diagnostyka · 29.06.2026 · 27 (2) · 1-13

DOI: 10.29354/diag/225190 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostyka, online erschienen am 29.06.2026. Verfasst von Tomasz Korbiel. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents an analysis of the impact of modern nonlinear loads on power quality in low-voltage networks supplying residential installations and local smart-grid systems. Particular attention is devoted to total harmonic distortion of input current (THDI) and power factor, treated as diagnostic indicators of the operating condition of low-voltage networks. The study is based on the assumption that rectifier-based input stages and switch-mode power supplies commonly used in electronic devices constitute major sources of power-quality disturbances. The research methodology consisted of two complementary stages. In the first stage, numerical modeling of simplified rectifier and switch-mode converter topologies was performed in the LTspice environment in order to analyze the mechanisms of harmonic generation and their influence on THDI and power factor. In the second stage, experimental measurements were conducted on selected consumer devices, including LED lamps, a fluorescent lamp, a charger, and a switch-mode power supply, operating under real network conditions characterized by distorted supply voltage. The results showed good qualitative agreement between numerical simulations and experimental measurements. Strongly impulsive input current waveforms and high THDI values were observed for loads equipped with rectifier-capacitor and switch-mode input stages. The measurements also confirmed that significant differences between devices were associated mainly with the topology of the input stage, while no simple monotonic relation with rated power was observed within the investigated set of loads. The obtained results indicate that THDI and power factor can be treated as useful diagnostic indicators of power-quality threats in contemporary low-voltage power systems.

Zitieren

APA

Korbiel, T. (2026). Sources of harmonic distortion in consumer power supply circuits and their impact on power quality in low-voltage smart grids. Diagnostyka, 27(2), 1-13. https://doi.org/10.29354/diag/225190

Vancouver

Korbiel T. Sources of harmonic distortion in consumer power supply circuits and their impact on power quality in low-voltage smart grids. Diagnostyka. 2026;27(2):1-13. doi:10.29354/diag/225190

BibTeX
@article{Korbiel2026,
  author = {Korbiel, Tomasz},
  title = {Sources of harmonic distortion in consumer power supply circuits and their impact on power quality in low-voltage smart grids},
  journal = {Diagnostyka},
  year = {2026},
  volume = {27},
  number = {2},
  pages = {1--13},
  doi = {10.29354/diag/225190}
}
Kostenlos starten →