EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

A Development of a Coarse Particle Concentration Measurement System Using a Crystal-Based Sensor and a Dust Sensor for Air Quality Measurement

Arif Budianto, Susi Rahayu, Laili Mardiana, Ramadian Ridho Illahi, Rosita Juniarti

Jurnal Pendidikan Fisika dan Teknologi · 02.06.2024 · 10 (1) · 10-15

DOI: 10.29303/jpft.v10i1.6692 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Jurnal Pendidikan Fisika dan Teknologi, online erschienen am 02.06.2024. Verfasst von Arif Budianto und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

QCM or quartz crystal microbalance is a non static crystal that can be used as a mass sensor. As a piezoelectric crystal, a QCM generates an electrical signal with a specific frequency. The frequency change can be utilized as a frequency counter in a mass measurement system. This study aims to develop a coarse particle sensor system using a QCM and an oscillator circuit. In line with this, this study uses an oscillator circuit and a QCM for a sensor development. Thus, the frequency measurement of the QCM contains an oscillator and a signal conditioner connected to a microcontroller. For this purpose, an Arduino Nano was used as the signal processing, while a QCM was used as a coarse particle sensor and compared to a digital dust sensor (Winsen ZH03). The sensor system was evaluated using a fixed-type crystal connected to an oscillator: 2.5 MHz - 7.2 MHz. Arduino Nano processed the frequency signal generated by the developed oscillator. The results show that the sensor system has a stable output signal compared to the comparator. There is a linear correlation between the frequency measured by the system and the oscilloscope (99.73%). It can be concluded that the sensor system can measure coarse particle concentrations from 32-620 ug/cm3 (frequencies from 2 MHz to 7.2 MHz) with a response time of 1 second. The system has an accuracy of 99% and a resolution of 1 Hz.

Zitieren

APA

Budianto, A., Rahayu, S., Mardiana, L., Illahi, R. R., & Juniarti, R. (2024). A Development of a Coarse Particle Concentration Measurement System Using a Crystal-Based Sensor and a Dust Sensor for Air Quality Measurement. Jurnal Pendidikan Fisika dan Teknologi, 10(1), 10-15. https://doi.org/10.29303/jpft.v10i1.6692

Vancouver

Budianto A, Rahayu S, Mardiana L, Illahi RR, Juniarti R. A Development of a Coarse Particle Concentration Measurement System Using a Crystal-Based Sensor and a Dust Sensor for Air Quality Measurement. Jurnal Pendidikan Fisika dan Teknologi. 2024;10(1):10-15. doi:10.29303/jpft.v10i1.6692

BibTeX
@article{Budianto2024,
  author = {Budianto, Arif and Rahayu, Susi and Mardiana, Laili and Illahi, Ramadian Ridho and Juniarti, Rosita},
  title = {A Development of a Coarse Particle Concentration Measurement System Using a Crystal-Based Sensor and a Dust Sensor for Air Quality Measurement},
  journal = {Jurnal Pendidikan Fisika dan Teknologi},
  year = {2024},
  volume = {10},
  number = {1},
  pages = {10--15},
  doi = {10.29303/jpft.v10i1.6692}
}
Kostenlos starten →