EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Behavior of R.C Slab-Column Connections with Square and Circular Columns under Gravity and Lateral Cyclic Loading Conditions

Abathar M. Al- Yaseri, Laith Al-Hadithy

Al-Nahrain Journal for Engineering Sciences · 20.06.2026 · 29 (2) · 198-208

DOI: 10.29194/njes.29020198 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Al-Nahrain Journal for Engineering Sciences, online erschienen am 20.06.2026. Verfasst von Abathar M. Al- Yaseri und 1 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This experimental investigation evaluates the structural behavior of reinforced concrete slab-column connections incorporating columns with square and circular cross-sectional geometries under gravity and lateral cyclic loading. Four interior slab-column specimens were designed, fabricated, and tested, with identical slab dimensions of 1050×1050×80 mm and a column height of 500 mm. The circular columns were intended to have an equivalent second moment of inertia to the square column, ensuring a fair comparison of geometric effects. One specimen identified as SC-G, incorporating a square column, was tested under a progressively increasing vertical load to determine its maximum gravity load-bearing capacity. The remaining three specimens SC-2 with a square tied column, SC-9 with a circular spirally-reinforced column, and SC-10 with a circular column incorporating a column capital were tested under a constant gravity load equivalent to 60% of SC-G’s ultimate capacity (75 kN), combined with a lateral displacement protocol conforming to ACI 374 guidelines. Results indicated that the shape of the column (circular) and reinforcement (spiral) in SC-9 produces a comparatively higher ultimate load, stiffness, and ductility than SC-2 of the square column and tied reinforcement. The ultimate lateral load increase was +13.3%, -26.1%. Circular spiral columns with column capital in slab-column connections led to a noticeable rise in ultimate lateral load by about +62%, -80%. It was also shown that incorporating a column capital in SC-10 significantly enhanced the punching shear resistance and energy dissipation capacity. Circular columns demonstrated more stable hysteretic behavior and improved ductility compared to the square column specimen.

Zitieren

APA

Yaseri, A. M. A., & Al-Hadithy, L. (2026). Behavior of R.C Slab-Column Connections with Square and Circular Columns under Gravity and Lateral Cyclic Loading Conditions. Al-Nahrain Journal for Engineering Sciences, 29(2), 198-208. https://doi.org/10.29194/njes.29020198

Vancouver

Yaseri AMA, Al-Hadithy L. Behavior of R.C Slab-Column Connections with Square and Circular Columns under Gravity and Lateral Cyclic Loading Conditions. Al-Nahrain Journal for Engineering Sciences. 2026;29(2):198-208. doi:10.29194/njes.29020198

BibTeX
@article{Yaseri2026,
  author = {Yaseri, Abathar M. Al- and Al-Hadithy, Laith},
  title = {Behavior of R.C Slab-Column Connections with Square and Circular Columns under Gravity and Lateral Cyclic Loading Conditions},
  journal = {Al-Nahrain Journal for Engineering Sciences},
  year = {2026},
  volume = {29},
  number = {2},
  pages = {198--208},
  doi = {10.29194/njes.29020198}
}
Kostenlos starten →