EUVIMEDEUVIMED entdecken
Crossref

Comparación de un método de quimioluminiscencia versus ELISA para la búsqueda de anticuerpos anti-Sm, en apoyo al diagnóstico del lupus eritematoso sistémico

REVISTA MÉDICA DEL URUGUAY · 19.05.2026 · 42 (2)

DOI: 10.29193/rmu.42.2.9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift REVISTA MÉDICA DEL URUGUAY, online erschienen am 19.05.2026.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Anti-Sm antibodies (Ab.) are highly specific for the diagnosis of systemic lupus erythematosus (SLE), although they occur infrequently. In cases of suspected systemic autoimmune disease, several guidelines recommend a stepwise testing protocol which, in clinical practice, is not always followed. The laboratory of the Asociación Española (Montevideo, Uruguay) began using the chemiluminescence method (CLIA), occasionally observing unexpected anti-Sm reactivities.

Objectives

The objectives were to determine the optimal cut-off of the CLIA method and to compare its diagnostic performance with ELISA for the detection of anti-Sm antibodies. Materials and methods: The CLIA cut-off was compared with ELISA and indirect immunofluorescence (IIF, ANA HEp-2) using a reference material. Anti-Sm antibodies were determined by CLIA and ELISA in 40 patient sera. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and the optimal CLIA cut-off were calculated by ROC curve analysis. In addition, chi-square, Cohen’s kappa coefficient, and R2 between CLIA and ELISA were calculated.

Results

The cut-offs found were: IIF 1/4096, CLIA 1/1024, and ELISA 1/512. The sensitivity of both CLIA and ELISA was 95%, whereas specificity was 93% and 100%, respectively. The PPV of CLIA and ELISA was 76% and 100%, respectively, and the NPV was 93% and 95%, respectively. The optimal CLIA cut-off was 41.5 CU (85% sensitivity and 95% specificity), chi-square was 18.2 (p < 0.01), the kappa coefficient was 0.65 (p < 0.01), and the R2 coefficient was 0.83 (p = 1.92 × 10^-16).

Conclusions

CLIA may be used as an alternative to ELISA for the detection of anti-Sm antibodies, provided that the method cut-off is adjusted to the population of each laboratory, using IIF, ANA HEp-2 either in parallel or in a stepwise manner.

Zitieren

APA

(2026). Comparación de un método de quimioluminiscencia versus ELISA para la búsqueda de anticuerpos anti-Sm, en apoyo al diagnóstico del lupus eritematoso sistémico. REVISTA MÉDICA DEL URUGUAY, 42(2). https://doi.org/10.29193/rmu.42.2.9

Vancouver

Comparación de un método de quimioluminiscencia versus ELISA para la búsqueda de anticuerpos anti-Sm, en apoyo al diagnóstico del lupus eritematoso sistémico. REVISTA MÉDICA DEL URUGUAY. 2026;42(2). doi:10.29193/rmu.42.2.9

BibTeX
@article{euvimed2026,
  title = {Comparación de un método de quimioluminiscencia versus ELISA para la búsqueda de anticuerpos anti-Sm, en apoyo al diagnóstico del lupus eritematoso sistémico},
  journal = {REVISTA MÉDICA DEL URUGUAY},
  year = {2026},
  volume = {42},
  number = {2},
  doi = {10.29193/rmu.42.2.9}
}
Kostenlos starten →