EUVIMEDEUVIMED entdecken
Crossref

Examination of Effective Frequency Band for Human Gait Recognition Using Lower Limb Biomechanical Signals

Chala Beyan Mohammed, Nurhan Gürsel Özmen

Uluslararası Muhendislik Arastirma ve Gelistirme Dergisi · 28.03.2026 · 18 (2) · 61-76

DOI: 10.29137/ijerad.1740443 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Uluslararası Muhendislik Arastirma ve Gelistirme Dergisi, online erschienen am 28.03.2026. Verfasst von Chala Beyan Mohammed und 1 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A human gait recognition system based on machine learning is an emerging field of biomechanics, with applications in robotics, prosthetic control, and rehabilitation. Choosing the optimal frequency band for EMG is crucial to improve model performance and reduce processing time. This study aims to identify the effective frequency band for EMG-based lower limb signal classification in gait recognition. An open-access dataset containing 50 healthy subjects is used, with 20 subjects selected across five activity types: Step Up, Step Down, Walking, Heel Walking, and Toe Walking. The activities are split into two groups of three-class and two-class sets. For each subject, two muscle groups, the Tibialis Anterior and the Gastrocnemius Medialis, are used. Eight time-domain features are extracted from both muscles, and classification is performed using three machine learning models: Support Vector Machine (SVM), Neural Networks (NN), and K-Nearest Neighbors (KNN). Three frequency bands: RAW data, 10-250Hz, and 250-400Hz are evaluated. The frequency band of 10-250Hz consistently provided the highest classification performance. In a two-class classification, a Neural Network (NN) achieved an accuracy of 0.97 for 10-250Hz. SVM and NN outperformed KNN in both activity groups. These findings suggest that selecting a proper frequency band for EMG-based machine learning classification enhances its effectiveness in human gait recognition, potentially aiding in the design and development of smarter prosthetic control systems and rehabilitation.

Zitieren

APA

Mohammed, C. B., & Özmen, N. G. (2026). Examination of Effective Frequency Band for Human Gait Recognition Using Lower Limb Biomechanical Signals. Uluslararası Muhendislik Arastirma ve Gelistirme Dergisi, 18(2), 61-76. https://doi.org/10.29137/ijerad.1740443

Vancouver

Mohammed CB, Özmen NG. Examination of Effective Frequency Band for Human Gait Recognition Using Lower Limb Biomechanical Signals. Uluslararası Muhendislik Arastirma ve Gelistirme Dergisi. 2026;18(2):61-76. doi:10.29137/ijerad.1740443

BibTeX
@article{Mohammed2026,
  author = {Mohammed, Chala Beyan and Özmen, Nurhan Gürsel},
  title = {Examination of Effective Frequency Band for Human Gait Recognition Using Lower Limb Biomechanical Signals},
  journal = {Uluslararası Muhendislik Arastirma ve Gelistirme Dergisi},
  year = {2026},
  volume = {18},
  number = {2},
  pages = {61--76},
  doi = {10.29137/ijerad.1740443}
}
Kostenlos starten →