Imprinted high-Q polymer micro-ring resonator array for high-resolution photoacoustic tomography
Opto-Electronic Advances · 2026 · 9 (6) · 250215
DOI: 10.29026/oea.2026.250215 ↗Kurz gefasst
Fachartikel in der Zeitschrift Opto-Electronic Advances, 2026. Verfasst von Hyeonwoo Kim und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering and Computer Sciences, University of Michigan, Ann Arbor 48109, USA. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDDK NIH HHS, NCI NIH HHS.
Abstract (Originalsprache)
We present the first demonstration of a polymer-based micro-ring resonator array with over 40 elements fabricated using nanoimprint lithography (NIL), and its application for photoacoustic tomography imaging. By precisely varying the radius of each micro-ring at the nanometer scale and maintaining its high-quality factor, we achieved distinguishable resonances within a free spectral range of only 2.19 nm. The micro-ring array was used to perform photoacoustic tomography (PAT), achieving lateral and axial resolutions of 40 μm and 38 μm, respectively, and an ultrasound response bandwidth of 173.5 MHz, and a noise equivalent pressure (NEP) of 13.5 Pa. PAT images of ex vivo mouse prostates were acquired by the micro-ring array, showing a high correlation with biological tissue structures and regions of blood vessels. Further spectral analysis of the PAT images can differentiate the prostate cancers from the normal prostates. This work highlights the significant advantages of using NIL-fabricated micro-ring resonator arrays made from polymer materials, demonstrating their potential for advanced applications in biomedical imaging as well as optical communications and integrated photonic systems.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Engineering and Computer Sciences, University of Michigan, Ann Arbor 48109, USA.
- Department of Biomedical Engineering, University of Michigan, Ann Arbor 48109, USA.
- Department of Radiology, University of Michigan, Ann Arbor 48109, USA.
- Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor 48105, USA.
Förderung
- NIDDK NIH HHS
- NCI NIH HHS
Zitieren
APA
Kim, H., Lin, W. K., Ni, L., Ali, M., Wang, X., Xu, G., & Guo, L. J. (2026). Imprinted high-Q polymer micro-ring resonator array for high-resolution photoacoustic tomography. Opto-Electronic Advances, 9(6), 250215. https://doi.org/10.29026/oea.2026.250215
Vancouver
Kim H, Lin WK, Ni L, Ali M, Wang X, Xu G, et al. Imprinted high-Q polymer micro-ring resonator array for high-resolution photoacoustic tomography. Opto-Electronic Advances. 2026;9(6):250215. doi:10.29026/oea.2026.250215
BibTeX
@article{Kim2026,
author = {Kim, Hyeonwoo and Lin, Wei-Kuan and Ni, Linyu and Ali, Mohammad and Wang, Xueding and Xu, Guan and Guo, L Jay},
title = {Imprinted high-Q polymer micro-ring resonator array for high-resolution photoacoustic tomography},
journal = {Opto-Electronic Advances},
year = {2026},
volume = {9},
number = {6},
pages = {250215},
doi = {10.29026/oea.2026.250215}
}
EUVIMED