Comparison of 2 Types of Bioabsorbable Implants Performing The Chevron Osteotomy to Treat Hallux Valgus Deformity: A Randomized Prospective Clinical Study
Journal of Orthopedic Research and Therapy · 2023
DOI: 10.29011/2575-8241.001292 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopedic Research and Therapy, 2023.
Abstract (Originalsprache)
Background
Chevron Osteotomy is a treatment option for realigning a mild hallux valgus deformity.There are multiple different ways to fix this osteotomy.We compared prospectively two different types of bioabsorbable screws for the fixation of the Chevron Osteotomy. Questions/purposes:The purpose of the study was to compare two types of bioabsorbable screws to stabilize the chevron osteotomy.In particular, we were interested in the stability of fixation, the absorbability of the implants without losing the initial angular correction of both IMA and HVA, complications with the hardware, and the healing process of both the osteotomy site and the soft tissue envelop, finally the patient satisfaction with the intervention. Patients and methods:We included patients between 19-90 years old with a mild to moderate hallux valgus deformity (IM angle I/II -15 degrees).Between Nov. 2016 and Oct. 2017, 71 patients were randomly assigned to either the Mg group or the PLLA group.Clinical, radiographic, and pedobarographic examinations were performed preoperatively, four weeks postoperatively, and two years postoperatively.
Results
The clinical improvement measured by AOFAS, FFI, and FAOS was statistically significant for all patients in both groups compared to the preoperative values.We observed a significant statistically unchanged correction of both IMA and HVA in both groups throughout the entire observation period.There were no malunions or loss of correction in both groups.We observed a screw fracture in 8 cases four weeks postoperatively; despite this finding, it did not affect the IMA, and HVA achieved correction.In one case, we had to replace a PLLA screw intraoperatively with a classic titanium headless screw due to intraoperative loss of compression.We also had one superficial infection in both groups and a deep infection in the Mg group that required implant removal. Conclusion:The Chevron osteotomy remains a sound and viable osteotomy correcting mild and moderate hallux valgus deformity.To our knowledge, this is the first study to compare Both resorbable screws and showed satisfying and comparable clinical and radiological midterm results.Screw fractures were observed with the magnesium-based implant.This occurrence could not be seen with the PLLA implant due to its biocomposite nature.Further research is needed with another radiological tool to understand the reason behind implant failure.
Zitieren
APA
(2023). Comparison of 2 Types of Bioabsorbable Implants Performing The Chevron Osteotomy to Treat Hallux Valgus Deformity: A Randomized Prospective Clinical Study. Journal of Orthopedic Research and Therapy. https://doi.org/10.29011/2575-8241.001292
Vancouver
Comparison of 2 Types of Bioabsorbable Implants Performing The Chevron Osteotomy to Treat Hallux Valgus Deformity: A Randomized Prospective Clinical Study. Journal of Orthopedic Research and Therapy. 2023. doi:10.29011/2575-8241.001292
BibTeX
@article{euvimed2023,
title = {Comparison of 2 Types of Bioabsorbable Implants Performing The Chevron Osteotomy to Treat Hallux Valgus Deformity: A Randomized Prospective Clinical Study},
journal = {Journal of Orthopedic Research and Therapy},
year = {2023},
doi = {10.29011/2575-8241.001292}
}
EUVIMED