Returning to diving and hyperbaric exposure after pulmonary vein isolation for atrial fibrillation
Diving and Hyperbaric Medicine Journal · 30.06.2026 · 56 (2) · 203-207
DOI: 10.28920/dhm56.2.203-207 ↗Kurz gefasst
Fallbericht in der Zeitschrift Diving and Hyperbaric Medicine Journal, online erschienen am 30.06.2026. Verfasst von Silvio Zerbi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Intensive Care, ASST Sette Laghi, Varese, Italy. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pulmonary Veins, Diving, Hyperbaric Oxygenation.
Abstract (Originalsprache)
Pulmonary vein isolation (PVI) is an established rhythm-control therapy for atrial fibrillation (AF), yet the electrophysiological response of post-PVI individuals exposed to hyperbaric environments remains undocumented. Similarly, the in-vivo performance of implantable loop recorders (ILRs) and external patch-based electrocardiographic (ECG) devices under increased ambient pressure has never been reported. We describe the first hyperbaric electrophysiology assessment in a post-PVI diver undergoing both underwater immersion and dry hyperbaric exposure with dual-modality cardiac rhythm monitoring. A 46-year-old experienced diver with successful PVI underwent: a scuba dive to 42 m in a warm water pool, monitored with a marinised 12-lead ECG Holter system; and a stepwise hyperbaric chamber compression to 284 kPa (2.8 atmospheres absolute) in ambient air, with single-lead surface ECG recordings obtained at static pressure plateaus. In both cases, the subject was monitored as well by his ILR. No AF recurrence or other dysrhythmias were detected during either exposure, with stable heart rate trends. The ILR maintained full functional integrity after both the 42 m dive and the 284 kPa chamber compression. The external ECG patch yielded interpretable tracings during static phases. Telemetry failed due to electromagnetic shielding by the steel chamber walls. This case suggests that carefully selected post-PVI individuals may tolerate controlled underwater and hyperbaric exposure without rhythm destabilisation. Both implantable and external monitoring devices preserved operational integrity under moderate hyperbaric conditions, providing a foundation for the emerging field of hyperbaric electrophysiology monitoring and informing fitness-to-dive assessment in post-ablation patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology and Intensive Care, ASST Sette Laghi, Varese, Italy.
- Corresponding author: Dr Silvio Zerbi, Department of Anesthesiology and Intensive Care. ASST Sette Laghi, Viale Borri, 57 - 21100 Varese (VA), Italy, silvio.zerbi@asst-settelaghi.it.
- Independent Researcher, Padova, Italy.
- Anesthesiology, Intensive Care and Hyperbaric Medicine, Policlinico Universitario "P. Giaccone", Palermo, Italy.
- UOC Centrale Operativa 118, ARNAS Civico, Palermo, Italy.
- Department of Medicine and Aging Sciences, University "G. D'Annunzio" Chieti - Pescara, Italy.
ORCID-Profile: Silvio Zerbi
Zitieren
APA
Zerbi, S., Tarsia, L., Benenati, V., Nicosia, D., Bosco, G., & Paganini, M. (2026). Returning to diving and hyperbaric exposure after pulmonary vein isolation for atrial fibrillation. Diving and Hyperbaric Medicine Journal, 56(2), 203-207. https://doi.org/10.28920/dhm56.2.203-207
Vancouver
Zerbi S, Tarsia L, Benenati V, Nicosia D, Bosco G, Paganini M. Returning to diving and hyperbaric exposure after pulmonary vein isolation for atrial fibrillation. Diving and Hyperbaric Medicine Journal. 2026;56(2):203-207. doi:10.28920/dhm56.2.203-207
BibTeX
@article{Zerbi2026,
author = {Zerbi, Silvio and Tarsia, Luigi and Benenati, Vincenzo and Nicosia, Dario and Bosco, Gerardo and Paganini, Matteo},
title = {Returning to diving and hyperbaric exposure after pulmonary vein isolation for atrial fibrillation},
journal = {Diving and Hyperbaric Medicine Journal},
year = {2026},
volume = {56},
number = {2},
pages = {203--207},
doi = {10.28920/dhm56.2.203-207}
}