The impact of different gas mixtures on inflammatory responses in advanced recreational divers
Diving and Hyperbaric Medicine Journal · 30.06.2021 · 51 (2) · 140-146
DOI: 10.28920/dhm51.2.140-146 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Diving and Hyperbaric Medicine Journal, online erschienen am 30.06.2021. Verfasst von Monica Rocco und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgical and Medical Science and Translation Medicine, Sapienza University, Rome, Italy. Hauptthemen laut MEDLINE: Decompression Sickness, Gases, Inflammation. Die Arbeit wurde bisher 7-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Introduction
Decompression sickness (DCS) is considered a ‘bubble disease’. Intravascular bubbles activate inflammatory responses associated with endothelial dysfunction. Breathing gas has been proposed as a potential risk factor but this is inadequately studied. Different gases are used in scuba diving. Helium-containing 'trimix' could theoretically mitigate inflammation and therefore reduce DCS risk. This study determined the effect of air and trimix on the inflammatory response following dives to 50 metres of sea water, and evaluated the differences between them in advanced recreational divers.
Methods
Thirty-three divers were enrolled in this observational study and were divided in two groups: 17 subjects were included in the air group, and 16 different subjects were included in the trimix (21% oxygen, 35% helium, 44% nitrogen) group. Each subject conducted a single dive, and both groups used a similar diving profile of identical duration. A venous blood sample was taken 30 min before diving and 2 h after surfacing to evaluate changes in interleukins (IL) IL-1α, IL-1β, IL-2, IL-4, IL-6, IL-8, IL-10, tumour necrosis factor α (TNFα), vascular endothelial growth factor (VEGF), Interferon γ (IFN-γ), monocyte chemoattractant protein 1 (MCP-1) and epithelial growth factor (EGF) after diving.
Results
No differences were observed between groups in demographic data or diving experience. Following the dive, IL-6 values showed a slight increase, while IL-8 and EGF decreased in both groups, without significant variation between the groups.
Conclusions
In physically fit divers, trimix and air gas mixture during deep diving did not cause relevant changes in the inflammatory markers tested.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Surgical and Medical Science and Translation Medicine, Sapienza University, Rome, Italy.
- Department of Anesthesia, Sant'Andrea Hospital, Rome, Italy.
- Corresponding author: Dr Luigi Maggi, Department of Anesthesia, Sant'Andrea Hospital, Rome, Italy, maggi.medicina@libero.it.
- Department of Neuroscience, Mental Health and Sensory Organs, Sapienza University, Rome, Italy.
Zitieren
APA
Rocco, M., Maggi, L., Loffredo, C., Pelli, M., Benedetto, P. D., Fiorelli, S., Simmaco, M., & De Blasi, R. A. (2021). The impact of different gas mixtures on inflammatory responses in advanced recreational divers. Diving and Hyperbaric Medicine Journal, 51(2), 140-146. https://doi.org/10.28920/dhm51.2.140-146
Vancouver
Rocco M, Maggi L, Loffredo C, Pelli M, Benedetto PD, Fiorelli S, et al. The impact of different gas mixtures on inflammatory responses in advanced recreational divers. Diving and Hyperbaric Medicine Journal. 2021;51(2):140-146. doi:10.28920/dhm51.2.140-146
BibTeX
@article{Rocco2021,
author = {Rocco, Monica and Maggi, Luigi and Loffredo, Chiara and Pelli, Massimiliano and Benedetto, Pia Di and Fiorelli, Silvia and Simmaco, Maurizio and De Blasi, Roberto Alberto},
title = {The impact of different gas mixtures on inflammatory responses in advanced recreational divers},
journal = {Diving and Hyperbaric Medicine Journal},
year = {2021},
volume = {51},
number = {2},
pages = {140--146},
doi = {10.28920/dhm51.2.140-146}
}
EUVIMED