EUVIMEDEUVIMED entdecken
Crossref

A FREQUENCY-AWARE CNN–VISION TRANSFORMER WITH ADAPTIVE MULTI-STREAM FEATURE FUSION AND UNCERTAINTY ESTIMATION FOR EEG SEIZURE DETECTION

Sachin Chawla, Rajeev Ranjan, Yogendra Narayan

JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCES · 20.05.2025 · 21 (5)

DOI: 10.26782/jmcms.2026.05.00002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCES, online erschienen am 16.05.2025. Verfasst von Sachin Chawla und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Automated seizure detection from scalp electroencephalography(EEG) remains challenging because EEG signals are non-stationary, noisy, highly imbalanced, and vary substantially across patients. This study aimed to develop a robust deep learning framework for seizure detection under clinically relevant, leakage-controlled evaluation settings.

Methods

We proposed a frequency-aware CNN–Vision Transformer (FA-CNNViT) framework integrating deterministic dataset harmonization, subject-wise leakage-controlled cross-validation, split-specific preprocessing, and post-split window generation. The model combines convolutional encoding for local morphological features with transformer-based modeling of long-range dependencies. An adaptive multi-stream feature fusion module was used to preserve temporal, spectral, and spatial information. Asymmetric focal loss addressed class imbalance, and Monte Carlo dropout was used to estimate predictive uncertainty.

Results

On the CHB-MIT dataset, FA-CNNViT achieved 99.13% accuracy, 99.10% sensitivity, 99.47% specificity, 99.55% F1-score, and 99.74% ROC-AUC. In the cross-subject setting on the Turkish EEG dataset, it achieved 89.98% accuracy, 87.41% sensitivity, 88.61% specificity, 87.44% F1- score, and 88.79% ROC-AUC.

Conclusion

The proposed framework achieved strong subject-wise performance and competitive cross-subject performance under a leakage-controlled evaluation protocol. Further refinement of false-positive control and prospective validation is needed before real-time clinical deployment.

Zitieren

APA

Chawla, S., Ranjan, R., & Narayan, Y. (2025). A FREQUENCY-AWARE CNN–VISION TRANSFORMER WITH ADAPTIVE MULTI-STREAM FEATURE FUSION AND UNCERTAINTY ESTIMATION FOR EEG SEIZURE DETECTION. JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCES, 21(5). https://doi.org/10.26782/jmcms.2026.05.00002

Vancouver

Chawla S, Ranjan R, Narayan Y. A FREQUENCY-AWARE CNN–VISION TRANSFORMER WITH ADAPTIVE MULTI-STREAM FEATURE FUSION AND UNCERTAINTY ESTIMATION FOR EEG SEIZURE DETECTION. JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCES. 2025;21(5). doi:10.26782/jmcms.2026.05.00002

BibTeX
@article{Chawla2025,
  author = {Chawla, Sachin and Ranjan, Rajeev and Narayan, Yogendra},
  title = {A FREQUENCY-AWARE CNN–VISION TRANSFORMER WITH ADAPTIVE MULTI-STREAM FEATURE FUSION AND UNCERTAINTY ESTIMATION FOR EEG SEIZURE DETECTION},
  journal = {JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCES},
  year = {2025},
  volume = {21},
  number = {5},
  doi = {10.26782/jmcms.2026.05.00002}
}
Kostenlos starten →