Simulation Of P&O Algorithm Mppt With Output Sensing Direct Control Method Using Cuk Converter
i-manager's Journal on Instrumentation and Control Engineering · 2013
DOI: 10.26634/jic.1.1.2079 ↗Kurz gefasst
Fachartikel in der Zeitschrift i-manager's Journal on Instrumentation and Control Engineering, 2013. Verfasst von Mukesh. Die Arbeit nennt 38 Literaturangaben.
Abstract (Originalsprache)
Energy generated from clean, efficient, and environment friendly resources has become one of the major challenges for engineers and scientists [1, 2] . Among all renewable energy sources, photovoltaic power systems attract more attention while greenhouse emissions are reduced [1] [2] [3] [4] . Regarding the endless aspect of solar energy, it is worth saying that solar energy is a unique solution for energy crisis. However, despite all the aforementioned advantages of solar power systems, they do not present desirable efficiency [5, 6] . The environmental effects such as temperature, irradiation, special characteristics of sunlight, dirt, shadow, and so on affect the performance of the photovoltaic (PV) system [7, 8] . Changes in insolation on panels due to fast climate changes such as cloudy weather and increase in ambient temperature can reduce the PV cell output power [9,10]. The PV system has poor efficiency so it operates at the Maximum Power Point Tracking (MPPT). There are a large number of algorithms that are able to track MPPs. Here Purturb and Observe (P&O) algorithm [11] [12][13][14] [15] [16] [17] [18] [19] [20] [21] [22] [23] [24] is recommended because of their simplicity and ease of implementation. By 1. Perturb and Observe (P&O)-MPPT Algorithm In the P&O algorithm [25-27] the operating voltage of the PV array is perturbed by a small increment, and the resulting change in power, ΔP, is measured. If ΔP is positive, then the perturbation of the operating voltage moved the PV array's operating point closer to the MPP. Thus, further voltage perturbations in the same direction (that is, with the same algebraic sign) should move the operating point toward the MPP. If ΔP is negative, the system operating point has moved away from the MPP, and the algebraic sign of the perturbation should be reverse to move back toward the MPP [21]. The advantages of P&O algorithm are simplicity and ease of implementation. The P&O MPPT algorithm which is shown in Figure1 has been implemented in MATLAB to track maximum power from the solar PV module. The PV cell converts energy in the photons of sunlight into electricity by means of the photoelectric phenomenon found in certain types of semiconductor materials such as silicon and selenium [1] . PV module characteristics are comprehensively discussed in [1, 4, 8, 18, 36, 37 , which indicate an exponential and nonlinear relation between the output current and voltage In this paper, the MPPT (Maximum Power Point Tracking) with resistive load is implemented in MATLAB with output sensing direct control method using Cuk converter. The simulated system consists of the BP SX 150S photovoltaic (PV) module, the ideal Cuk converter, the MPPT control, and the resistive load (6Ω). The selection of the Purturb & Observe (P&O) algorithm permits the use of output sensing control method which eliminates the input voltage and current sensors. The direct control method adjusts the duty cycle within the MPP tracking algorithm. The way to adjust the duty cycle is totally based on the theory of load matching. When the value of R matches with that of R , the maximum power transfer from PV to load opt the load will occur. These two are, however, independent and rarely matches in practice. The goal of the MPPT is to match the impedance of load to the optimal impedance of PV.
Zitieren
APA
Mukesh (2013). Simulation Of P&O Algorithm Mppt With Output Sensing Direct Control Method Using Cuk Converter. i-manager's Journal on Instrumentation and Control Engineering. https://doi.org/10.26634/jic.1.1.2079
Vancouver
Mukesh. Simulation Of P&O Algorithm Mppt With Output Sensing Direct Control Method Using Cuk Converter. i-manager's Journal on Instrumentation and Control Engineering. 2013. doi:10.26634/jic.1.1.2079
BibTeX
@article{Mukesh2013,
author = {Mukesh},
title = {Simulation Of P&O Algorithm Mppt With Output Sensing Direct Control Method Using Cuk Converter},
journal = {i-manager's Journal on Instrumentation and Control Engineering},
year = {2013},
doi = {10.26634/jic.1.1.2079}
}
EUVIMED