Abstract (Originalsprache)
In power systems, protection of the electrical equipment and the need for reliable operation play a major role. Modern power transmission line protection schemes include feature to detect and locate faults on lines accurately for facilitating post fault repairs and identification of weak spots in the system. Fault detection should be done initially, followed by accurate fault location. Many fault detection algorithms have been proposed over the years for improving the reliability of protection schemes. The fault detection can be done using either voltage/current signals or travelling waves in relaying. A moving sum based approach which uses the principle that the integral of a current/voltage signal under normal state approximately zero is presented in [1]. If this sum deviates beyond a predetermined value, fault is recorded. A cumulative sum (CUSUM) based approach is proposed in [2] that defines an index which increases proportionally with the fault current and if it crosses certain threshold value, the By algorithm treats it as a fault. Transmission line fault location has long been one of the primary concerns of the power industry. The use of traveling wave theory for fault detection was initially proposed by Dommel and Michels in [3], where a discriminate was defined based on the transient voltage and current waveforms in order to detect a transmission line fault. McLaren and S.Rajendra [4] have developed a correlation based technique where the cross correlation between stored sections of the forward and backward traveling waves were used to estimate the travel times of transient signals from the relays to the fault point [4, 5]. The wavelet transform is applied to analyze power system transient and extraction of their particular features in [6, 7]. A detailed review of different fault location techniques based on compensated and uncompensated transmission lines is presented in [8, 9, and 10]. In this paper, a moving sum and cumulative-sum (CUSUM)based fault detectors are analyzed for power transmission line relaying applications. The moving sum and cumulative sum methods are tested and employed widely for detecting abrupt changes due to faults in power system. A
Zitieren
APA
Sk.Nazeer (2013). Performance Of Fault Detection And Location Algorithms For Power Transmission Lines. i-manager's Journal on Circuits and Systems. https://doi.org/10.26634/jcir.1.2.2292
Vancouver
Sk.Nazeer. Performance Of Fault Detection And Location Algorithms For Power Transmission Lines. i-manager's Journal on Circuits and Systems. 2013. doi:10.26634/jcir.1.2.2292
BibTeX
@article{SkNazeer2013,
author = {Sk.Nazeer},
title = {Performance Of Fault Detection And Location Algorithms For Power Transmission Lines},
journal = {i-manager's Journal on Circuits and Systems},
year = {2013},
doi = {10.26634/jcir.1.2.2292}
}
EUVIMED