Fuzzy Based Power Quality Improvement In Grid Connected Microgrid At The Distribution Level
i-manager's Journal on Circuits and Systems · 2013
DOI: 10.26634/jcir.1.2.2288 ↗Kurz gefasst
Fachartikel in der Zeitschrift i-manager's Journal on Circuits and Systems, 2013. Die Arbeit nennt 14 Literaturangaben.
Abstract (Originalsprache)
The widespread use of non-linear loads is leading to a variety of undesirable phenomena in the operation of power systems. The harmonic components in current and voltage waveforms are the most important among these. Conventionally, passive filters have been used to eliminate line current harmonics. However, they introduce resonance in the power system and tend to be bulky. So active power line conditioners have become popular than passive filters as it compensates the harmonics and reactive power simultaneously. The active power filter topology can be connected in series or shunt and combinations of both. Shunt active filter is more popular than series active filter because most of the industrial applications require current harmonics compensation. Different types of active filters have been proposed to increase the electric system quality. A generalized block diagram of active power filter is presented in Figure 2 . The classification is based on the following criteria. • Power rating and speed of response required in compensated system. • System parameters to be compensated (e.g. current harmonics, power factor , voltage harmonics) • Technique used for estimating the reference current/voltage. Current controlled voltage source inverters can be utilized with appropriate control strategy to perform active filter functionality. The electrical grid will include a very large number of small producers that use renewable energy sources like solar panels or wind generators. One of the most common problems when connecting small renewable energy systems to the electric grid concerns the interface unit between the power sources and the grid, because it can inject harmonic components that may detoriate the power quality [1], [2] . However, the extensive use of power electronics based equipment and non-linear loads at PCC generate harmonic currents, which may detoriate the quality power. In [3] an inverter operates as active inductor at a certain frequency to absorb the harmonic current. A similar approach in which a shunt active filter acts as active conductance to damp out the harmonics in distribution network is proposed [4], [5] . The proposed system consists of RES connected to the dclink of a grid-interfacing inverter as shown in Figure 1 . The voltage source inverter is a key element of a DG system as it interfaces the renewable energy source to the grid and delivers the generated power. The RES may be a DC source or an AC source with rectifier coupled to dc-link. Usually, the fuel cell and photovoltaic energy sources generate power
Zitieren
APA
(2013). Fuzzy Based Power Quality Improvement In Grid Connected Microgrid At The Distribution Level. i-manager's Journal on Circuits and Systems. https://doi.org/10.26634/jcir.1.2.2288
Vancouver
Fuzzy Based Power Quality Improvement In Grid Connected Microgrid At The Distribution Level. i-manager's Journal on Circuits and Systems. 2013. doi:10.26634/jcir.1.2.2288
BibTeX
@article{euvimed2013,
title = {Fuzzy Based Power Quality Improvement In Grid Connected Microgrid At The Distribution Level},
journal = {i-manager's Journal on Circuits and Systems},
year = {2013},
doi = {10.26634/jcir.1.2.2288}
}