A Review On Control Strategies For Lfc In Deregulated Scenario
i-manager's Journal on Circuits and Systems · 2013
DOI: 10.26634/jcir.1.1.2197 ↗Kurz gefasst
Fachartikel in der Zeitschrift i-manager's Journal on Circuits and Systems, 2013. Verfasst von T. Anil Kumar. Die Arbeit nennt 34 Literaturangaben.
Abstract (Originalsprache)
In power system any sudden load disturbance causes deviation of frequency and tie line power exchange. Therefore, the load frequency control is plays crucial role in power system operation and control for supplying quality and continuity of power to the consumer. The main objective of LFC is to maintain load frequency and tie-line power flow within permissible limits by adjusting the steam input of generators so as to accommodate as per the requirement of fluctuating load demands. In recent years, Electric power industry is transformed to deregulated environment. Because of privatisation of power sector, the world is moving towards deregulation of power industry. It is necessary to provide better service, quality and continuity of supply, so that the power industry is undergoing significant electrical reforms which adversely affect economy of the country. In deregulated industry, there are more number of pool players and buyers. Consumer has the opportunity to select better service provider among the pool. Open Market Environment is the collection of unrestricted rules and economic benefits provided to sellers to provide better service and reliable supply. Power system under restructured scenario consists of GENCO's, TRANSCO's and ISO's. In this paper, different control strategies have been discussed such as conventional, Modern Feedback controllers, Adaptive controllers, intelligent controllers, robust controllers and investigated LFC problem in deregulated environment with different ancillaries. In this paper, the salient features of each control strategy are thoroughly discussed and their relative advantages and disadvantages are discussed. In this paper, section1 represents the modelling of deregulated system for LFC problem. In section2 various control techniques for LFC are described. In section3, control strategies for LFC problem in deregulated environment with different ancillaries are discussed. In section4, LFC schemes with HVDC link are discussed. In the open market environment of the power system the Vertically Integrated Utility (VIU) no longer exists. Deregulated system consists of GENCOs, DISCOs, transmission companies and Independent System Operators (ISO). However the common goal is to keep frequency constant. In this paper deregulated system contains two areas. Each area consists of two generators and also two discos as shown in Figure1. The block diagram of generalized LFC scheme for a two area deregulated ABSTRACT In power system studies, Load frequency control is an important issue to supply sufficient and reliable electric power with good quality. The main objective of LFC is to maintain load frequency and tie-line power flow within permissible limits by adjusting megawatt output of LFC generators, so as to accommodate fluctuating load demands. This paper presents a brief review of different control techniques to researchers on design of LFC controllers in deregulated environment. The overview of different control strategies are explained in brief, such as Classical and Modern feedback controllers, Adaptive, Intelligent and Robust control strategies along with their relative advantages and disadvantages. Finally, incorporating Facts devices and Energy storage devices in the investigation of LFC problem have also been discussed.
Zitieren
APA
Kumar, T. A. (2013). A Review On Control Strategies For Lfc In Deregulated Scenario. i-manager's Journal on Circuits and Systems. https://doi.org/10.26634/jcir.1.1.2197
Vancouver
Kumar TA. A Review On Control Strategies For Lfc In Deregulated Scenario. i-manager's Journal on Circuits and Systems. 2013. doi:10.26634/jcir.1.1.2197
BibTeX
@article{Kumar2013,
author = {Kumar, T. Anil},
title = {A Review On Control Strategies For Lfc In Deregulated Scenario},
journal = {i-manager's Journal on Circuits and Systems},
year = {2013},
doi = {10.26634/jcir.1.1.2197}
}
EUVIMED