EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Assessing Shoulder Proprioceptive Sense of Force: Hand-Held Dynamometer Reliability and Comparison with Isokinetic Protocols

Xavier Amen, Jean-Sébastien Roy, Stéphane Baudry, Dominique Mouraux, Joachim Van Cant

International Journal of Sports Physical Therapy · 02.03.2025 · 20 (3)

DOI: 10.26603/001c.129585 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Sports Physical Therapy, online erschienen am 02.03.2025. Verfasst von Xavier Amen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Rehabilitation Lab Université Libre de Bruxelles. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Proprioception is crucial for shoulder stability, yet clinical methods for assessing all aspects, particularly the sense of force (SOF) -the ability to perceive, interpret, and reproduce force at a joint-are limited. The purpose of this study was to test a new SOF protocol with a handheld dynamometer (HHD) and examine its agreement with an isokinetic dynamometer (IKD), as well as its reliability and the effect of contraction intensity.

Design

Cross-sectional measurement study.

Methods

Fifty-one healthy participants were assessed for SOF using an Isokinetic dynamometer (IKD) and a HHD to evaluate the agreement between the two methods. Of the initial sample, 25 participants completed a second session with the HHD, enabling the evaluation of the protocol’s reliability exclusively with this device. Error score were also compared between three different contraction intensities: 10%, 30% and 50% of maximal voluntary isometric contraction (MVIC). Intra-class correlation coefficients (ICCs), standard error of measurement (SEM), and minimal detectable change (MDC) for intra-rater (within-day and between-day) and inter-rater (within-day) reliability while agreement between the tools was assessed using regression line method.

Results

Agreement between devices was low with a poor correlation observed between measurements. The HHD SOF protocol showed low to moderate reliability for intra-rater between-day assessments, with ICCs from 0.44 to 0.64. The absolute reliability MDC95 ranged from 12% to 42%. Inter-rater within-day reliability was low, with ICCs from 0.007 to 0.43. Significant differences in error scores were observed between the HHD and IKD at 30% and 50% MVIC, and higher error scores were noted at Target 10% MVIC compared to 30% and 50%.

Conclusions

The SOF protocol using HHD demonstrates moderate reliability but low inter-rater reliability. Different tools yield varying results, with force intensity impacting SOF error scores, while rotation does not. Level of evidence 2b

Schlagwörter

Stichwörter der Autor:innen

ProprioceptionSense of forceShoulderreliability

Autor:innen und Institutionen

  • Rehabilitation Lab Université Libre de Bruxelles.
  • École des sciences de la réadaptation, Faculté de médecine Université Laval, Quebec City.
  • Centre for Interdisciplinary Research in Rehabilitation and Social Integration.
  • Faculty of Human Motor Sciences, Laboratory of Applied Biololgy and Research Unit in Applied Neurophysiology (LABNeuro) Université Libre de Bruxelles.
  • Faculty of Human Motor Sciences, Research Unit in Rehabilitation Sciences Université Libre de Bruxelles.

Zitieren

APA

Amen, X., Roy, J. S., Baudry, S., Mouraux, D., & Van Cant, J. (2025). Assessing Shoulder Proprioceptive Sense of Force: Hand-Held Dynamometer Reliability and Comparison with Isokinetic Protocols. International Journal of Sports Physical Therapy, 20(3). https://doi.org/10.26603/001c.129585

Vancouver

Amen X, Roy JS, Baudry S, Mouraux D, Van Cant J. Assessing Shoulder Proprioceptive Sense of Force: Hand-Held Dynamometer Reliability and Comparison with Isokinetic Protocols. International Journal of Sports Physical Therapy. 2025;20(3). doi:10.26603/001c.129585

BibTeX
@article{Amen2025,
  author = {Amen, Xavier and Roy, Jean-Sébastien and Baudry, Stéphane and Mouraux, Dominique and Van Cant, Joachim},
  title = {Assessing Shoulder Proprioceptive Sense of Force: Hand-Held Dynamometer Reliability and Comparison with Isokinetic Protocols},
  journal = {International Journal of Sports Physical Therapy},
  year = {2025},
  volume = {20},
  number = {3},
  doi = {10.26603/001c.129585}
}
Kostenlos starten →