EUVIMEDEUVIMED entdecken
Crossref

High Resolution Ultrasound Radiomics Differences in Carotid Plaques between Patients with and without Ischemic Stroke

Shenglan Yang, Xiaoyu Luo, Wendi Zheng, Xiaoyu Yue, Wenhao Liu, Yanan Pan, Yichun Zhou, Xiaoyu Wan, Mingjun Xu, Mei Zhang

Advanced Ultrasound in Diagnosis and Therapy · 2026-12 · 10 (4) · 233-244

DOI: 10.26599/audt.2026.260034 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Ultrasound in Diagnosis and Therapy, online erschienen am 29.10.2026. Verfasst von Shenglan Yang und 9 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

High-resolution ultrasound (HRUS) provides improved spatial resolution for superficial vascular structures, while radiomics quantifies image intensity and texture patterns. However, the robustness of HRUS radiomics differences between carotid plaques from patients with and without ischemic stroke (IS) remains uncertain. This study aimed to identify radiomics features robustly associated with IS.

Methods

This retrospective study included a primary cohort of 1,148 patients (361 with IS and 787 without IS) and an additional population of 83 patients with IS and moderate or severe carotid plaque. We extracted 474 radiomics features in the primary cohort. Features meeting the reliability criterion were analyzed primarily using propensity score overlap weighting for eight clinical covariates. Associations were also assessed using covariate adjusted logistic regression, with false discovery rate correction applied to the overlap-weighted and covariate-adjusted analyses. LASSO selection stability was evaluated in bootstrap samples after penalty selection by the one standard error rule. A separate 1,000 iteration bootstrap of the full modeling pipeline provided internal validation. An expanded clinical model, interaction analyses, and a comparison of the two IS case cohorts were also performed.

Results

A total of 412 of 474 features (86.9%) met the ICC threshold of 0.80. After overlap weighting, all eight clinical covariates had absolute standardized mean differences below 0.01 (effective sample size = 817.2). Of the 403 estimable features, 73 were associated with IS after false discovery rate correction. Seven features in the primary cohort met all robustness criteria. Wavelet-LH_glrlm_RunEntropy showed the strongest inverse association in the weighted analysis (OR per SD, 0.60; 95% CI, 0.49 to 0.74; q < 0.001). In the expanded clinical model, all seven features retained the same association direction, and one remained significant after false discovery rate correction.

Conclusion

HRUS radiomics profiles differed between patients with and without IS in the overlap-weighted analysis. Seven features met the prespecified robustness criteria. These findings suggest that plaque echogenicity and spatial texture are associated with IS. Prospective multicenter validation is needed.

Zitieren

APA

Yang, S., Luo, X., Zheng, W., Yue, X., Liu, W., Pan, Y., Zhou, Y., Wan, X., Xu, M., & Zhang, M. (2026). High Resolution Ultrasound Radiomics Differences in Carotid Plaques between Patients with and without Ischemic Stroke. Advanced Ultrasound in Diagnosis and Therapy, 10(4), 233-244. https://doi.org/10.26599/audt.2026.260034

Vancouver

Yang S, Luo X, Zheng W, Yue X, Liu W, Pan Y, et al. High Resolution Ultrasound Radiomics Differences in Carotid Plaques between Patients with and without Ischemic Stroke. Advanced Ultrasound in Diagnosis and Therapy. 2026;10(4):233-244. doi:10.26599/audt.2026.260034

BibTeX
@article{Yang2026,
  author = {Yang, Shenglan and Luo, Xiaoyu and Zheng, Wendi and Yue, Xiaoyu and Liu, Wenhao and Pan, Yanan and Zhou, Yichun and Wan, Xiaoyu and Xu, Mingjun and Zhang, Mei},
  title = {High Resolution Ultrasound Radiomics Differences in Carotid Plaques between Patients with and without Ischemic Stroke},
  journal = {Advanced Ultrasound in Diagnosis and Therapy},
  year = {2026},
  volume = {10},
  number = {4},
  pages = {233--244},
  doi = {10.26599/audt.2026.260034}
}
Kostenlos starten →