Modeling of turbine operating modes of the stretch-out operation for VVER-1000 power unit
Global Nuclear Safety · 22.03.2026 · 16 (1) · 61-68
DOI: 10.26583/gns-2026-01-07 ↗Kurz gefasst
Fachartikel in der Zeitschrift Global Nuclear Safety, online erschienen am 22.03.2026. Verfasst von G. N. Nikitas und 2 weiteren Autor:innen. Die Arbeit nennt 8 Literaturangaben.
Abstract (Originalsprache)
The relevance of this study is determined by the necessity to minimize economic losses resulting from reduced electricity output during the stretch-out operation of VVER-1000 power units. The objective of the work is to analyze the efficiency of utilizing the sliding pressure mode in the second circuit to release additional reactivity through the temperature effect and to increase electricity generation. A comprehensive mathematical model has been developed, incorporating reactivity balance equations (considering temperature and power effects), heat balance and heat transfer equations for the steam generator, and the Stodola–Flügel equation for steam flow rate. The simulation is performed using the United Cycle CAD system, where the thermal schematic of the K-1000-60/1500-2 turbine unit was created and verified. A comparative assessment of three extended campaign modes is conducted: power reduction at constant pressure, the sliding pressure mode, and a combined sliding pressure mode with staged disconnection of high-pressure heater (HPH) groups. The simulation is carried out for the range of reactor thermal power reduction corresponding to the extended campaign period. It is established that the application of sliding pressure with HPH disconnection allows maintaining a higher level of electrical power compared to the base mode, thereby providing a significant additional economic effect. Concurrently, an increase in exhaust steam moisture content at the turbine outlet is identified, which necessitates coordination with the manufacturer. A staged schedule for HPH disconnection is proposed, ensuring optimal mode management based on the criterion of maximizing power output. The implementation of this technology is most relevant for NPPs located in southern regions characterized by higher condenser pressure. The obtained results can be utilized in the development of operational documentation and the safety justification for extended campaigns of VVER-1000 power units.
Zitieren
APA
Nikitas, G. N., Lapkis, A. A., & Ozerny, D. A. (2026). Modeling of turbine operating modes of the stretch-out operation for VVER-1000 power unit. Global Nuclear Safety, 16(1), 61-68. https://doi.org/10.26583/gns-2026-01-07
Vancouver
Nikitas GN, Lapkis AA, Ozerny DA. Modeling of turbine operating modes of the stretch-out operation for VVER-1000 power unit. Global Nuclear Safety. 2026;16(1):61-68. doi:10.26583/gns-2026-01-07
BibTeX
@article{Nikitas2026,
author = {Nikitas, G. N. and Lapkis, A. A. and Ozerny, D. A.},
title = {Modeling of turbine operating modes of the stretch-out operation for VVER-1000 power unit},
journal = {Global Nuclear Safety},
year = {2026},
volume = {16},
number = {1},
pages = {61--68},
doi = {10.26583/gns-2026-01-07}
}
EUVIMED