Methodical approach to setting limits and monitoring the power of critical test facility according to radiation safety conditions
Global Nuclear Safety · 22.03.2026 · 16 (1) · 5-14
DOI: 10.26583/gns-2026-01-01 ↗Kurz gefasst
Fachartikel in der Zeitschrift Global Nuclear Safety, online erschienen am 22.03.2026. Verfasst von A. G. Vasiatkin und 4 weiteren Autor:innen. Die Arbeit nennt 6 Literaturangaben.
Abstract (Originalsprache)
The article considers the specifics of establishing operating limits and safe operating limits in terms of power for critical test facilities during neutron-physical tests of propulsion reactor cores. Based on an aspect-oriented analysis, it is shown that within the power range typical of critical assemblies, the thermal and structural aspects do not determine the choice of the limiting power, whereas the radiation aspect becomes decisive. The relationship between neutron power, the measured neutronic characteristics, and the readings of ionization chambers is analyzed, and two stages that are critical from the standpoint of radiation safety are identified: operation of the critical assembly at power and personnel handling of fuel assemblies after their removal. It is shown that at constant neutron power, the dose rate measured by the radiation monitoring system in the critical facility room may remain nearly unchanged as it is governed primarily by prompt radiation components and biological shielding. At the same time, the dose-rate characteristics of fuel assemblies after irradiation are determined by the accumulated activity of fission products and activation products and depend on the irradiation history. It is substantiated that the maximum permissible operating conditions should be defined as allowable «power–operating time» combinations linked to the predicted dose rate from fuel assemblies and to the limits applicable to transport packages. The use of a digital twin of the critical assembly is proposed for the prompt prediction of dose-rate characteristics, which calculates the dose rate from fuel assemblies based on the irradiation history. The methodology makes it possible to relate protection setpoints and test regimes to objective radiation safety criteria, reduce uncertainty at the stage of fuel-assembly removal, and ensure the required accuracy of neutron-physical measurements when expanding the range of tested core types.
Zitieren
APA
Vasiatkin, A. G., Belin, A. V., Sosnin, M. A., Molodtsov, A. A., & Kamnev, M. A. (2026). Methodical approach to setting limits and monitoring the power of critical test facility according to radiation safety conditions. Global Nuclear Safety, 16(1), 5-14. https://doi.org/10.26583/gns-2026-01-01
Vancouver
Vasiatkin AG, Belin AV, Sosnin MA, Molodtsov AA, Kamnev MA. Methodical approach to setting limits and monitoring the power of critical test facility according to radiation safety conditions. Global Nuclear Safety. 2026;16(1):5-14. doi:10.26583/gns-2026-01-01
BibTeX
@article{Vasiatkin2026,
author = {Vasiatkin, A. G. and Belin, A. V. and Sosnin, M. A. and Molodtsov, A. A. and Kamnev, M. A.},
title = {Methodical approach to setting limits and monitoring the power of critical test facility according to radiation safety conditions},
journal = {Global Nuclear Safety},
year = {2026},
volume = {16},
number = {1},
pages = {5--14},
doi = {10.26583/gns-2026-01-01}
}