EUVIMEDEUVIMED entdecken
Crossref

Atypical Finishing with Lower Incisor Missing and Lower Primary Canine Retained using Improved Super-Elastic Ti-Ni Alloy Wire and Aligners

Lo Yu-Cheng, Chen Yuan-Hou, Chiang Hsien-Hsiung, Yu Jian-Hong

Dental Research and Oral Health · 2019

DOI: 10.26502/droh.0012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Dental Research and Oral Health, 2019. Verfasst von Lo Yu-Cheng und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

This is an atypical finish case with extraction of bilateral deciduous canines and three incisor finishing due to lower lateral incisor congenital missing replaced by 1st premolars. We used improved super-elastic Ti-Ni alloy wire (ISW) for anterior anchorage preparation during the molar mesial drive. Aligners for finishing and detailing were adopted because patient was ordered to an international expatriate job. We are going to discuss the mechanism we used, atypical finishing consideration and timing for aligners using.

Findings

This case report describes an adult female patient with lower incisor missing, lower bilateral primary canines retained, and dental crossbite. All were treated successfully with improved super-elasticity Ti-Ni alloy wire and aligners.

Conclusions

After the treatment, a desirable outcome was achieved and the patient was pleased with the treatment result. To sum up, wire orthodontics (WO) and aligner orthodontics (AO) will be a flexible and humanity treatment strategy for patients in the future.

Zitieren

APA

Yu-Cheng, L., Yuan-Hou, C., Hsien-Hsiung, C., & Jian-Hong, Y. (2019). Atypical Finishing with Lower Incisor Missing and Lower Primary Canine Retained using Improved Super-Elastic Ti-Ni Alloy Wire and Aligners. Dental Research and Oral Health. https://doi.org/10.26502/droh.0012

Vancouver

Yu-Cheng L, Yuan-Hou C, Hsien-Hsiung C, Jian-Hong Y. Atypical Finishing with Lower Incisor Missing and Lower Primary Canine Retained using Improved Super-Elastic Ti-Ni Alloy Wire and Aligners. Dental Research and Oral Health. 2019. doi:10.26502/droh.0012

BibTeX
@article{YuCheng2019,
  author = {Yu-Cheng, Lo and Yuan-Hou, Chen and Hsien-Hsiung, Chiang and Jian-Hong, Yu},
  title = {Atypical Finishing with Lower Incisor Missing and Lower Primary Canine Retained using Improved Super-Elastic Ti-Ni Alloy Wire and Aligners},
  journal = {Dental Research and Oral Health},
  year = {2019},
  doi = {10.26502/droh.0012}
}
Kostenlos starten →