Investigation of laser irradiation power and beam angle on Ni-Cr metals in improving shear-bond strength of adhesive bridge
Journal of Baghdad College of Dentistry · 15.06.2026 · 38 (2) · 64-76
DOI: 10.26477/jbcd.v38i2.4219 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Baghdad College of Dentistry, online erschienen am 15.06.2026. Verfasst von Winnie Munte und 3 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Laser irradiation has been widely utilized in the modification of material surfaces by altering their microstructure and topography, however, the effect of irradiation parameters such as power output and beam angle to bonding performance of metallic substrates remain insufficiently understood, especially for Ni-Cr metals.
Objectives
This study aimed to evaluate the effects of diode laser power in different beam angles on the surface of Nickel-Chromium (Ni-Cr) metals to improve bonding strength of adhesive bridge. Materials and Methods: Thirty-six cylindrical Ni-Cr metals, with a thickness of 2.0-3.0 mm, and 36 post-extraction maxillary premolars were divided into 6 groups (n=6). A diode laser irradiation was performed on metal samples with beam-angles of 30°, 60°, and 90° and powers of 2.0 watts and 4.0 watts. Teeth were then cemented into metal samples using resin cement. After treatment, shear-bond strength (SB-Strength) testing was carried out using a Universal Testing Machine (UTM). Meanwhile, the samples also were evaluated using Scanning Electron Microscope (SEM) and Atomic Force Microscope (AFM). Data were analyzed using a T-test, ANOVA test, and LSD test.
Results
A significant SB-strength was found in 30° for 2.0 watt and 90° for 4.0 watt respectively 4.48±1.97 MPa and 5.27±2.50 MPa. Morphological analysis suggested that 30° allows more uniform surface roughness, while 90°allows similar patterns but with higher depth.
Conclusion
These results provide practical guidance for clinicians by indicating that perpendicular laser irradiation (90°) at controlled power settings may improve bonding reliability in adhesive bridge procedures involving Ni–Cr frameworks
Zitieren
APA
Munte, W., Tamin, H. Z., Nasution, I., & Ritonga, P. W. (2026). Investigation of laser irradiation power and beam angle on Ni-Cr metals in improving shear-bond strength of adhesive bridge. Journal of Baghdad College of Dentistry, 38(2), 64-76. https://doi.org/10.26477/jbcd.v38i2.4219
Vancouver
Munte W, Tamin HZ, Nasution I, Ritonga PW. Investigation of laser irradiation power and beam angle on Ni-Cr metals in improving shear-bond strength of adhesive bridge. Journal of Baghdad College of Dentistry. 2026;38(2):64-76. doi:10.26477/jbcd.v38i2.4219
BibTeX
@article{Munte2026,
author = {Munte, Winnie and Tamin, Haslinda Z and Nasution, Indra and Ritonga, Putri WU},
title = {Investigation of laser irradiation power and beam angle on Ni-Cr metals in improving shear-bond strength of adhesive bridge},
journal = {Journal of Baghdad College of Dentistry},
year = {2026},
volume = {38},
number = {2},
pages = {64--76},
doi = {10.26477/jbcd.v38i2.4219}
}
EUVIMED