EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of Colorimetric Analysis Software for 2.2.2-Kryptofix Compliance Testing in [18F]FDG Production

Aude Longtin

McGill Science Undergraduate Research Journal · 10.04.2026 · 21 (2)

DOI: 10.26443/msurj.v21i2.473 ↗

Kurz gefasst

Fachartikel in der Zeitschrift McGill Science Undergraduate Research Journal, online erschienen am 10.04.2026. Verfasst von Aude Longtin. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

[18F]fluorodexyglucose ([18F]FDG) is a glucose analog where the hydroxyl group in the C-2 position is substituted by the cyclotron-produced [18F] radionuclide. This radiopharmaceutical is used in medical imaging, particularly in positron emission tomography (PET) scans crucial in cancer diagnoses and monitoring. 18F-FDG synthesis involves a nucleophilic substitution with 2.2.2-Kryptofix as a phase-transfer catalyst. However, Kryptofix residue quantities must be strictly regulated due to their toxicity. Current quality control processes employ spot testing where sample colors are compared to that of a standard, which is prepared at maximal Kryptofix concentration of 0.5mg/V. This project aims to build a user-friendly interface able to determine whether a 18[F]FDG sample passes the Kryptofix concentration test through image analysis techniques. A Python-based application was developed using the “Tkinter” library to create a graphical user interface, integrated with image processing features. The software employs colorimetric analysis by quantifying pixel intensity and performing statistical comparisons on user-defined cross-sections of the image. Software validation is performed using images with known sample and standard concentrations. The user-friendly interface aims to improve accessibility and limit the subjectivity of human analysis for the determination of 2.2.2-Kryptofix contents in a sample and successfully determines the pass/fail status of the sample regarding regulatory safety standards of 0.5mg/V. The software generates reports documenting the analytical process, which are required for regulatory compliance and quality assurance documentation. These reports are crucial in the case of a test failure or deviation. Further improvements can be made to the software to quantify the Kryptofix concentration in [18F]FDG samples rather than provide only pass/fail data. The basic software architecture has also been adapted and modified to conduct other quality control tests in a radiopharmaceutical laboratory, with promising preliminary testing for bacterial colony counting and environmental monitoring.

Zitieren

APA

Longtin, A. (2026). Development of Colorimetric Analysis Software for 2.2.2-Kryptofix Compliance Testing in [18F]FDG Production. McGill Science Undergraduate Research Journal, 21(2). https://doi.org/10.26443/msurj.v21i2.473

Vancouver

Longtin A. Development of Colorimetric Analysis Software for 2.2.2-Kryptofix Compliance Testing in [18F]FDG Production. McGill Science Undergraduate Research Journal. 2026;21(2). doi:10.26443/msurj.v21i2.473

BibTeX
@article{Longtin2026,
  author = {Longtin, Aude},
  title = {Development of Colorimetric Analysis Software for 2.2.2-Kryptofix Compliance Testing in [18F]FDG Production},
  journal = {McGill Science Undergraduate Research Journal},
  year = {2026},
  volume = {21},
  number = {2},
  doi = {10.26443/msurj.v21i2.473}
}
Kostenlos starten →