EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Automated Microtubule Detection for Subtomogram Averaging in Cryo-Electron Tomography

Yining 'Molly' Yu, Khanh Huy Bui

McGill Science Undergraduate Research Journal · 10.04.2026 · 21 (2)

DOI: 10.26443/msurj.v21i2.461 ↗

Kurz gefasst

Fachartikel in der Zeitschrift McGill Science Undergraduate Research Journal, online erschienen am 10.04.2026. Verfasst von Yining 'Molly' Yu und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cryo-electron tomography enables three-dimensional visualization of macromolecular structures within intact cells. Filamentous structures such as microtubules are essential for intracellular transport, structural stability, and cell division. Structural analysis of microtubules often relies on subtomogram averaging, a process that requires manual or semi-manual filament picking and alignment. These steps are time-consuming, computationally demanding, and can introduce user bias, making it difficult to handle large datasets efficiently. We developed an automated pipeline for microtubule detection and particle orientation prediction to improve efficiency and consistency in subtomogram averaging workflows. The pipeline integrates filament tracing, line connection analysis, and geometric modeling to detect microtubules and predict particle angles prior to alignment. Quality control measures were incorporated to identify elliptical distortions, misaligned particles, and outliers in dense datasets. Performance was evaluated by comparing pipeline outputs with manually processed datasets, examining particle ordering, angular consistency, alignment behavior, resolution, and processing time. Automated picking preserved expected structural organization and produced angle predictions consistent with refined alignment parameters while reducing analysis time. However, performance may vary depending on tomogram quality and filament density. These findings demonstrate that automated filament detection can reduce manual effort and support efficient structural analysis in cryo-electron tomography. Further improvements may increase reliability across different cellular contexts.

Zitieren

APA

Yu, Y. M., & Bui, K. H. (2026). Automated Microtubule Detection for Subtomogram Averaging in Cryo-Electron Tomography. McGill Science Undergraduate Research Journal, 21(2). https://doi.org/10.26443/msurj.v21i2.461

Vancouver

Yu YM, Bui KH. Automated Microtubule Detection for Subtomogram Averaging in Cryo-Electron Tomography. McGill Science Undergraduate Research Journal. 2026;21(2). doi:10.26443/msurj.v21i2.461

BibTeX
@article{Yu2026,
  author = {Yu, Yining 'Molly' and Bui, Khanh Huy},
  title = {Automated Microtubule Detection for Subtomogram Averaging in Cryo-Electron Tomography},
  journal = {McGill Science Undergraduate Research Journal},
  year = {2026},
  volume = {21},
  number = {2},
  doi = {10.26443/msurj.v21i2.461}
}
Kostenlos starten →