Design of A Portable Air Conditioning System for Localised Cooling Using R134A
AFRICAN JOURNAL OF APPLIED RESEARCH · 09.07.2026 · 12 (5) · 363-377
DOI: 10.26437/1gftts51 ↗Kurz gefasst
Fachartikel in der Zeitschrift AFRICAN JOURNAL OF APPLIED RESEARCH, online erschienen am 09.07.2026. Verfasst von M. R. M. Iqbal und 1 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Purpose
The purpose of this research is to design, fabricate, and investigate the performance of a portable air-conditioning system for localised cooling. Design/methodology/approach: In this study, a portable air conditioning system is designed to operate on a Vapour-Compression Refrigeration (VCRS) cycle and use R134a refrigerant. The closed chamber, measuring 6ft x 6ft x 6ft, was fabricated to simulate a closed-chamber environment. A full factorial Design of Experiments (DoE) approach was utilised, and internal heat load, air velocity, and insulation thickness were identified as independent parameters for the study. The dependent parameters were compressor work, refrigeration effect, net cooling capacity, and Coefficient of Performance (COP). For evaluating the localised cooling performance of a portable air conditioning system, this study introduced internal heat load, insulation thickness, and controlled air velocity as a combined optimisation parameter. Research limitation: This research is limited to R134a refrigerant with a portable air conditioning system for localised cooling.
Findings
It was found that the portable air conditioning system’s performance was significantly affected by all the input parameters. As the internal heat load increases, the compressor work increases, thereby decreasing the system's COP. At the same time, higher air velocity increases heat transfer and reduces cooling time. This research also found the optimum combinations of independent parameters. The COP of the system is significantly improved by 18-22% when the thickness of the insulation is increased from 15mm to 40 mm due to lower compressor workload and reduced thermal leakage. Practical Implication: The fabricated system demonstrates its feasibility in confined spaces and could be a better alternative to traditional air-cooling methods. Social Implication: In densely populated urban areas where demand is continuously rising, this system can contribute to sustainable cooling and energy efficiency. Originality / Value: This research integrates Design of Experiments (DoE)- based optimisation of internal heat load, insulation thickness, and airflow to improve localised cooling performance and energy efficiency.
Zitieren
APA
Iqbal, M. R. M., & Nanvala, H. (2026). Design of A Portable Air Conditioning System for Localised Cooling Using R134A. AFRICAN JOURNAL OF APPLIED RESEARCH, 12(5), 363-377. https://doi.org/10.26437/1gftts51
Vancouver
Iqbal MRM, Nanvala H. Design of A Portable Air Conditioning System for Localised Cooling Using R134A. AFRICAN JOURNAL OF APPLIED RESEARCH. 2026;12(5):363-377. doi:10.26437/1gftts51
BibTeX
@article{Iqbal2026,
author = {Iqbal, M. R. M. and Nanvala, H.},
title = {Design of A Portable Air Conditioning System for Localised Cooling Using R134A},
journal = {AFRICAN JOURNAL OF APPLIED RESEARCH},
year = {2026},
volume = {12},
number = {5},
pages = {363--377},
doi = {10.26437/1gftts51}
}