EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Effect of Drop Panels and Shear Reinforcement around Openings and Columns on Punching Shear Resistance: A Design-Oriented Numerical Case Study Based on ACI 318-19

Suhaib Ahmad Ali Alzyoud

مجلة العلوم الهندسية و تكنولوجيا المعلومات · 15.03.2026 · 10 (1) · 102-112

DOI: 10.26389/ajsrp.b091225 ↗

Kurz gefasst

Fachartikel in der Zeitschrift مجلة العلوم الهندسية و تكنولوجيا المعلومات, erschienen am 15.03.2026. Verfasst von Suhaib Ahmad Ali Alzyoud. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents a design-oriented numerical case study investigating the punching shear behavior of reinforced concrete flat slabs, focusing on the combined effects of drop panels, shear reinforcement (shear hooks), and slab openings located near slab–column connections. Punching shear is a brittle and critical failure mode, particularly when openings disturb stress flow near columns. A reinforced concrete flat slab with a thickness of 230 mm supported by an interior rectangular column (300 × 800 mm) was analyzed using manual calculations in accordance with ACI 318-19 and numerical modeling using SAFE software. The initial configuration without a drop panel resulted in an unsafe punching shear ratio of 1.36. Introducing a 100 mm drop panel increased the effective depth and critical shear perimeter, reducing the ratio to approximately 1.01, satisfying code requirements. Although the slab became technically safe after adding the drop panel, Ø10 mm shear hooks were provided around the column and near opening edges to enhance ductility, improve crack control, and increase robustness against unexpected load redistribution. A parametric numerical assessment was conducted by varying drop panel thickness, hook spacing, and opening location to examine their influence on punching shear demand. Based on the numerical results, practical design recommendations are proposed, including the use of drop panels at slab–column connections with nearby openings, placing the first row of shear hooks within 0.5d from the column face, and reducing hook spacing to ≤ 0.5d in regions affected by openings. The findings provide direct guidance for structural engineers involved in flat slab design within the framework of ACI 318-19.

Zitieren

APA

Alzyoud, S. A. A. (2026). Effect of Drop Panels and Shear Reinforcement around Openings and Columns on Punching Shear Resistance: A Design-Oriented Numerical Case Study Based on ACI 318-19. مجلة العلوم الهندسية و تكنولوجيا المعلومات, 10(1), 102-112. https://doi.org/10.26389/ajsrp.b091225

Vancouver

Alzyoud SAA. Effect of Drop Panels and Shear Reinforcement around Openings and Columns on Punching Shear Resistance: A Design-Oriented Numerical Case Study Based on ACI 318-19. مجلة العلوم الهندسية و تكنولوجيا المعلومات. 2026;10(1):102-112. doi:10.26389/ajsrp.b091225

BibTeX
@article{Alzyoud2026,
  author = {Alzyoud, Suhaib Ahmad Ali},
  title = {Effect of Drop Panels and Shear Reinforcement around Openings and Columns on Punching Shear Resistance: A Design-Oriented Numerical Case Study Based on ACI 318-19},
  journal = {مجلة العلوم الهندسية و تكنولوجيا المعلومات},
  year = {2026},
  volume = {10},
  number = {1},
  pages = {102--112},
  doi = {10.26389/ajsrp.b091225}
}
Kostenlos starten →