EUVIMEDEUVIMED entdecken
Crossref

Assessment of Maxillary Sinus Pneumatization in Dentate and Edentulous Areas Using Cone Beam Computed Tomography

Catherine Ramundo

VCU Scholars Compass (Virginia Commonwealth University) · 01.01.2024

DOI: 10.25772/2b59-xs36 ↗

Kurz gefasst

Fachartikel in der Zeitschrift VCU Scholars Compass (Virginia Commonwealth University), erschienen am 01.01.2024. Verfasst von Catherine Ramundo.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The primary goal of this retrospective analysis is to analyze the morphologic changes that occur following extraction in regards to sinus pneumatization.

Methods

The patient population was selected from the VCU School of Dentistry Graduate Periodontics Department. Cone Beam Computed Tomography scans (CBCT) was obtained from patients that had a posterior tooth extracted. A horizontal tangent line was drawn to the inferior border of the nasal cavity, acting as a constant reference point for measuring the extent of maxillary sinus pneumatization. Radiographic measurements were performed from a horizontal line at this fixed anatomical marker to the deepest level of the maxillary sinus pneumatization at the second premolar, first molar, or second molar sites.

Results

Results showed that the edentulous site had a statistically significantly greater amount of pneumatization of 1.7mm. There were no significant differences between tooth sites. There was no significant difference between preserved versus nonpreserved sites, but there was a trend towards less pneumatization at preserved sites (0.3mm) vs nonpreserved sites (1.8mm).

Conclusion

This preliminary study showed a significant difference between sinus pneumatization at edentulous sites compared to the contralateral sites. The extraction of a posterior teeth displayed a significant increase in sinus pneumatization compared to the contralateral dentate site of 1.7 mm. Ridge preservation at time of extraction showed a trend towards less sinus pneumatization of 0.3mm vs 1.8mm at non-preserved sites. This shows preliminary data that ridge preservation could help mitigate dimension changes of sinus pneumatization following extractions as well.

Schlagwörter

maxillary sinus pneumatizationtooth extractionedentulous sitesalveolar ridge preservationposterior teethmaxillary sinus floorcone-beam computed tomography

Zitieren

APA

Ramundo, C. (2024). Assessment of Maxillary Sinus Pneumatization in Dentate and Edentulous Areas Using Cone Beam Computed Tomography. VCU Scholars Compass (Virginia Commonwealth University). https://doi.org/10.25772/2b59-xs36

Vancouver

Ramundo C. Assessment of Maxillary Sinus Pneumatization in Dentate and Edentulous Areas Using Cone Beam Computed Tomography. VCU Scholars Compass (Virginia Commonwealth University). 2024. doi:10.25772/2b59-xs36

BibTeX
@article{Ramundo2024,
  author = {Ramundo, Catherine},
  title = {Assessment of Maxillary Sinus Pneumatization in Dentate and Edentulous Areas Using Cone Beam Computed Tomography},
  journal = {VCU Scholars Compass (Virginia Commonwealth University)},
  year = {2024},
  doi = {10.25772/2b59-xs36}
}
Kostenlos starten →