EUVIMEDEUVIMED entdecken
Crossref

Quality-by-Design assisted Green RP-HPLC Method for Simultaneous Estimation of Oxidative and Nitroso Impurities of Fezolinetant in pharmaceutical formulations

Krishna Mohan M.V., Rasheed Babu Shaik, Kiran Kumar Byram, Parvathi V., Haritha Potluri

Research Journal of Chemistry and Environment · 30.06.2026 · 30 (8) · 12

DOI: 10.25303/308rjce012024 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Research Journal of Chemistry and Environment, online erschienen am 30.06.2026. Verfasst von Krishna Mohan M.V. und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A green and analytical quality-by-design (AQbD)- assisted RP-HPLC method was developed and validated for the simultaneous estimation of Fezolinetant (FZNT) and its oxidative and nitroso impurities such as N-oxide (NOI), S-oxide (SOI), desfluoro impurity (DFI) and nitroso impurity (NI-1). The risk assessment suggests that the buffer strength, mobile phase pH and flow rate were the critical method parameters that influence the separation. The Box– Behnken design was utilized to optimize the chromatographic conditions. The developed quadratic models were highly significant (p < 0.0001) with excellent predictive capability (R² = 0.9925 for resolution between NOI–SOI and 0.9950 for FZNT– DFI). The response surface analysis shows that flow rate and mobile phase pH significantly influenced resolution whereas buffer strength produced quadratic effects. The chromatographic separation was achieved on Inertsil C18 column (250 × 4.6 mm, 5 µm) with UV detection at 246 nm. In the optimized conditions (10 mM buffer, pH 3.5, 0.8 mL/min), all analytes were well observed to be well resolved and resolution values were observed to be of 4.12 (between NOI–SOI) and 3.2 (between FZNT–DFI). The validation study proves the excellent specificity, linearity (R² > 0.999), precision (%RSD < 2%) and accuracy (98–102% recovery) of the proposed method. The LOD and LOQ were observed to be 0.012 µg/mL and 0.040 µg/mL respectively for impurities. Robustness and solution stability studies prove the reliability of the proposed method. Greenness assessment using AGREE (0.86), AGREE Prep (0.88), Complex GAPI and RGB-12 (78.1%) models proves the strong compliance of proposed method with green and white analytical chemistry principles. In conclusion, this method was rapid, reliable, environmentally sustainable and suitable for routine quality control analysis of FZNT and its impurities.

Zitieren

APA

M.V., K. M., Shaik, R. B., Byram, K. K., V., P., & Potluri, H. (2026). Quality-by-Design assisted Green RP-HPLC Method for Simultaneous Estimation of Oxidative and Nitroso Impurities of Fezolinetant in pharmaceutical formulations. Research Journal of Chemistry and Environment, 30(8), 12. https://doi.org/10.25303/308rjce012024

Vancouver

M.V. KM, Shaik RB, Byram KK, V. P, Potluri H. Quality-by-Design assisted Green RP-HPLC Method for Simultaneous Estimation of Oxidative and Nitroso Impurities of Fezolinetant in pharmaceutical formulations. Research Journal of Chemistry and Environment. 2026;30(8):12. doi:10.25303/308rjce012024

BibTeX
@article{MV2026,
  author = {M.V., Krishna Mohan and Shaik, Rasheed Babu and Byram, Kiran Kumar and V., Parvathi and Potluri, Haritha},
  title = {Quality-by-Design assisted Green RP-HPLC Method for Simultaneous Estimation of Oxidative and Nitroso Impurities of Fezolinetant in pharmaceutical formulations},
  journal = {Research Journal of Chemistry and Environment},
  year = {2026},
  volume = {30},
  number = {8},
  pages = {12},
  doi = {10.25303/308rjce012024}
}
Kostenlos starten →