Agreement of Noninvasive Multimodality Imaging Measurements With Balloon Sizing in the Cardiac Catheterization Laboratory Prior to Percutaneous Pulmonary Valve Implantation
Journal of Invasive Cardiology · 2026
DOI: 10.25270/jic/26.00166 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Invasive Cardiology, 2026. Verfasst von Sruti Rao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiology, Helen Devos Children's Hospital, Grand Rapids, Michigan.
Abstract (Originalsprache)
OBJECTIVES: Right ventricular outflow tract (RVOT) dysfunction is common in repaired congenital heart defects resulting in right ventricular (RV) dilation and dysfunction. Emerging transcatheter options enable placement of a competent pulmonary valve, obviating the need for surgery. Multimodality imaging plays a key role in determining the type and timing of intervention prior to percutaneous pulmonary valve implantation (PPVI). The authors sought to assess correlation of noninvasive RVOT measurements with cardiac magnetic resonance imaging (CMR) and cardiac computed tomography (CT) with balloon sizing in the catheterization laboratory prior to PPVI. METHODS: A retrospective review was performed on patients who had undergone PPVI with preprocedural CMR and cardiac CT scan. Three-dimensional multiplanar reconstruction (MPR) of the narrowest RVOT diameter on magnetic resonance angiography (MRA), whole heart sequence (WHS) images, and CT scan images were performed using commercially available software; balloon sizing prior to PPVI was recorded. Concordance correlation coefficients were used to assess agreement with the clinically acceptable limit between the modalities set at +/- 2 mm. Additionally, mean difference was used to quantify the difference in measurements among the 2 modalities. RESULTS: For maximal waist dimensions, correlation between MRA and WHS images with balloon sizing was 0.70 to 0.79, while correlation between CT scan and balloon sizing was 0.65 to 0.75. For minimal waist dimensions, correlation between MRA and WHS images was 0.72 to 0.82; correlation between CT scan and balloon sizing was 0.64 to 0.73. CONCLUSIONS: Cardiac CT and CMR are complementary modalities that provide essential information for preprocedural planning for PPVI.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatric Cardiology, Helen Devos Children's Hospital, Grand Rapids, Michigan.
- Department of Pediatric Cardiology, Cleveland Clinic Children's Hospital, Cleveland, Ohio.
- Department of Quantitative Health Sciences, Cleveland Clinic, Cleveland, Ohio.
- Department of Pediatric Cardiology, Nicklaus Children's Hospital, Miami, Florida.
- Department of Cardiovascular Imaging, Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio.
- Department of Pediatric Cardiology, Cleveland Clinic Children's Hospital, Cleveland, Ohio; Email: komarlr@ccf.org.
Zitieren
APA
Rao, S., Suntharos, P., Liu, W., Prieto, L., Worley, S., Schoenhagen, P., & Komarlu, R. (2026). Agreement of Noninvasive Multimodality Imaging Measurements With Balloon Sizing in the Cardiac Catheterization Laboratory Prior to Percutaneous Pulmonary Valve Implantation. Journal of Invasive Cardiology. https://doi.org/10.25270/jic/26.00166
Vancouver
Rao S, Suntharos P, Liu W, Prieto L, Worley S, Schoenhagen P, et al. Agreement of Noninvasive Multimodality Imaging Measurements With Balloon Sizing in the Cardiac Catheterization Laboratory Prior to Percutaneous Pulmonary Valve Implantation. Journal of Invasive Cardiology. 2026. doi:10.25270/jic/26.00166
BibTeX
@article{Rao2026,
author = {Rao, Sruti and Suntharos, Patcharapong and Liu, Wei and Prieto, Lourdes and Worley, Sarah and Schoenhagen, Paul and Komarlu, Rukmini},
title = {Agreement of Noninvasive Multimodality Imaging Measurements With Balloon Sizing in the Cardiac Catheterization Laboratory Prior to Percutaneous Pulmonary Valve Implantation},
journal = {Journal of Invasive Cardiology},
year = {2026},
doi = {10.25270/jic/26.00166}
}
EUVIMED