EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudie

Operator Radiation Dose Comparing Left Radial Artery and Right Radial Artery Approaches Among Patients With Subclavian Tortuosity

Richard Casazza, Bilal Malik, Arsalan Hashmi, Joshua Fogel, Enrico Montagna, Darren Gibson, Andres Palacio, Habiba Beginyazova, Robert Frankel, Jacob Shani

Journal of Invasive Cardiology · 2025

DOI: 10.25270/jic/25.00143 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Journal of Invasive Cardiology, 2025. Verfasst von Richard Casazza und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Maimonides Medical Center, Brooklyn, New York. Email: rcasazza@maimo.org. Hauptthemen laut MEDLINE: Radiation Exposure, Occupational Exposure.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Operator radiation exposure (ORE) is one of the most adverse occupational hazards faced by interventional cardiologists. The presence of subclavian tortuosity can influence ORE. METHODS: This single-center retrospective study compared the cumulative radiation (CR) exposure in μSv and normalized radiation exposure (CR/DAP) of the primary operator during cardiac catheterization of all patients with subclavian tortuosity from left (LRA) and right radial artery approaches (RRA). ORE was measured at 4 anatomical locations: thorax, abdomen, left eye, and right eye. RESULTS: CR dose was significantly higher in the RRA group than in the LRA group at the left eye (P = .004), right eye (P = .01), thorax (P = .01) and abdomen (P = .01). CR/DAP dose was significantly higher in the RRA group than in the LRA group at the left eye (P = .04) and right eye (P = .03). CONCLUSIONS: In cases with subclavian tortuosity, the LRA was associated with less CR to the operator than the RRA. The LRA was also associated with less CR/DAP that persisted at the anatomical location of the left eye. The authors recommend operators have time thresholds to exchange for appropriate catheters in patients with subclavian tortuosity. Furthermore, operators should consider time thresholds to change access sites to avoid potential procedural complications and excessive fluoroscopic times.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation ExposureOccupational ExposureHumansCardiologistsRetrospective StudiesSubclavian ArteryCoronary AngiographyRadiation DosageEyeMaleFemaleMiddle AgedAgedAged, 80 and overCardiac Catheterization

Stichwörter der Autor:innen

radial arteryradiation exposuretortuosity

Autor:innen und Institutionen

  • Department of Cardiology, Maimonides Medical Center, Brooklyn, New York. Email: rcasazza@maimo.org.
  • Department of Cardiology, Maimonides Medical Center, Brooklyn, New York.
  • Department of Management, Marketing, and Entrepreneurship, Brooklyn College, Brooklyn, New York.

Zitieren

APA

Casazza, R., Malik, B., Hashmi, A., Fogel, J., Montagna, E., Gibson, D., Palacio, A., Beginyazova, H., Frankel, R., & Shani, J. (2025). Operator Radiation Dose Comparing Left Radial Artery and Right Radial Artery Approaches Among Patients With Subclavian Tortuosity. Journal of Invasive Cardiology. https://doi.org/10.25270/jic/25.00143

Vancouver

Casazza R, Malik B, Hashmi A, Fogel J, Montagna E, Gibson D, et al. Operator Radiation Dose Comparing Left Radial Artery and Right Radial Artery Approaches Among Patients With Subclavian Tortuosity. Journal of Invasive Cardiology. 2025. doi:10.25270/jic/25.00143

BibTeX
@article{Casazza2025,
  author = {Casazza, Richard and Malik, Bilal and Hashmi, Arsalan and Fogel, Joshua and Montagna, Enrico and Gibson, Darren and Palacio, Andres and Beginyazova, Habiba and Frankel, Robert and Shani, Jacob},
  title = {Operator Radiation Dose Comparing Left Radial Artery and Right Radial Artery Approaches Among Patients With Subclavian Tortuosity},
  journal = {Journal of Invasive Cardiology},
  year = {2025},
  doi = {10.25270/jic/25.00143}
}
Kostenlos starten →