EUVIMEDEUVIMED entdecken
Crossref

Kissing-Catheter Technique in Percutaneous Transcatheter Closure of Patent Ductus Arteriosus: A Snare-Free Approach

Chen Zhang, Lingxiao Chen, Hong Gu

Journal of Invasive Cardiology · 2024

DOI: 10.25270/jic/24.00129 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Invasive Cardiology, 2024. Verfasst von Chen Zhang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China. Email: 021zhangchen@126.com. Hauptthemen laut MEDLINE: Ductus Arteriosus, Patent, Cardiac Catheterization, Septal Occluder Device.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: For percutaneous closure of the patent ductus arteriosus (PDA) with a mushroom-shaped occluder, the establishment of a guidewire rail with the antegrade venous approach may be difficult in some cases. The retrograde technique can be used instead; however, the use of a snare system may bring extra costs and risks. The aim of the study was to report on a new method that fulfills the retrograde technique without the use of a snare system in transcatheter closure of PDA. METHODS: From May 2019 to January 2023, we attempted transcatheter closure using the kissing-catheter technique after failure of the conventional antegrade venous approach on 22 consecutive patients with PDA. This technique involves docking the distal ends of the antegrade catheter and retrograde catheter in the main pulmonary artery, and sending an exchange guidewire from one catheter, through the docking junction, and externalized from the proximal end of the other. Then an artery-PDA-vein guidewire loop was established for the delivery of the occluder. The results and operation time of this method were analyzed. RESULTS: Successful establishment of the guidewire rail was achieved in all patients. The average time from attempting to dock the 2 catheters to successfully passing the guidewire was 26 ± 15 seconds. There were no complications during or after the procedures. CONCLUSIONS: The snare-free kissing-catheter technique is an efficient and reliable method for transcatheter closure of PDA in cases where the antegrade approach is difficult.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ductus Arteriosus, PatentCardiac CatheterizationSeptal Occluder DeviceHumansFemaleMaleRetrospective StudiesTreatment OutcomeChildChild, PreschoolAdultAdolescentPulmonary Artery

Stichwörter der Autor:innen

congenital heart diseasepatent ductus arteriosuspercutaneous closuretranscatheter closure

Autor:innen und Institutionen

  • Department of Pediatric Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China. Email: 021zhangchen@126.com.
  • Department of Pediatric Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.

Zitieren

APA

Zhang, C., Chen, L., & Gu, H. (2024). Kissing-Catheter Technique in Percutaneous Transcatheter Closure of Patent Ductus Arteriosus: A Snare-Free Approach. Journal of Invasive Cardiology. https://doi.org/10.25270/jic/24.00129

Vancouver

Zhang C, Chen L, Gu H. Kissing-Catheter Technique in Percutaneous Transcatheter Closure of Patent Ductus Arteriosus: A Snare-Free Approach. Journal of Invasive Cardiology. 2024. doi:10.25270/jic/24.00129

BibTeX
@article{Zhang2024,
  author = {Zhang, Chen and Chen, Lingxiao and Gu, Hong},
  title = {Kissing-Catheter Technique in Percutaneous Transcatheter Closure of Patent Ductus Arteriosus: A Snare-Free Approach},
  journal = {Journal of Invasive Cardiology},
  year = {2024},
  doi = {10.25270/jic/24.00129}
}
Kostenlos starten →