Retained foreign bodies in spine surgery: Never events, near never events, but not just adverse events
Surgical Neurology International · 05.06.2026 · 17 · 338
DOI: 10.25259/sni_593_2026 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Surgical Neurology International, online erschienen am 05.06.2026. Verfasst von Nancy E Epstein und 1 weiteren Autor:innen. Beteiligte Einrichtung: Professor of Clinical Neurosurgery, School of Medicine, State University of NY at Stony Brook, NY, c/o Dr. Marc Agulnick 1122 Franklin Avenue Suite 1…. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Themen: Patientensicherheit
Abstract (Originalsprache)
Background
Retained foreign bodies (RFB), or those left behind following spine surgery, are considered “Never Events (NE < 1/1000: they should never happen),” or “Near Never Events (NNE < 1/100; they should nearly never happen)”, but are not just “Adverse Events (AE >/= 1/100).” The vast majority of NE/NNE are due to cotton sponges, cottonoids, or residual cotton strands (i.e., collectively called Textilomas or Gossypibomas). However, RFB additionally included; fractured needles, guidewires, fractured screws/implants/drains, and/or broken instruments (i.e., scalpels). Notably, the spine surgeon of record, as captain of the ship, is primarily liable for RFB and is central to ensuing medicolegal suits. However, secondarily liable are the adjunctive surgical/medical personnel, (i.e., physicians, Physician Assistants, Nurses, Nurse Practitioners, Physical Therapists, Occupational Therapists), and others who are independent or work full-time for hospitals.
Methods
Patients with RFB may present with acute, subacute, or chronic/delayed pain and suffering. Additional complaints include; lost wages, sustained physical disability and/or injury attributed to these objects. Most RFB are diagnosed on plain X-rays, followed by MR and/or CT studies.
Results
RBS’s may include; retained drain fragments, broken needles, fractured guidewires, broken scalpel blades, fractured screws, and/or instruments. Retrieval procedures warrant a wide variety of different techniques, some of which fail. Notably, RFB’s largely occur due to the performance of; emergent procedures, doing an unfamiliar operation, encountering anatomical variants, or operating on patients with elevated body mass indexes (BMI). Additionally these include; surgeons’ failure to order and/or radiologists’ failure to correctly read intraoperative X-rays/fluoroscopic images, and/or nurses’ failures to correctly perform end of surgery counts.
Conclusion
RFBs, or foreign bodies left behind following spine surgery, are considered “Never Events (< 1/1000)” or “Near Never Events (< 1/100),” and are not just “Adverse Events (> 1/100)”. When they do occur, the operating surgeon bears primary responsibility, but the nursing/adjunctive staff and hospital are also liable.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Professor of Clinical Neurosurgery, School of Medicine, State University of NY at Stony Brook, NY, c/o Dr. Marc Agulnick 1122 Franklin Avenue Suite 106, Garden City, NY 11530, USA and Editor-in-Chief Surgical Neurology…
- Assistant Clinical Professor of Orthopedics, NYU Langone Hospital Long Island, NY, USA, 1122 Franklin Avenue, Suite 106, Garden City, NY 11530, USA.
Zitieren
APA
Epstein, N. E., & Agulnick, M. A. (2026). Retained foreign bodies in spine surgery: Never events, near never events, but not just adverse events. Surgical Neurology International, 17, 338. https://doi.org/10.25259/sni_593_2026
Vancouver
Epstein NE, Agulnick MA. Retained foreign bodies in spine surgery: Never events, near never events, but not just adverse events. Surgical Neurology International. 2026;17:338. doi:10.25259/sni_593_2026
BibTeX
@article{Epstein2026,
author = {Epstein, Nancy E and Agulnick, Marc A},
title = {Retained foreign bodies in spine surgery: Never events, near never events, but not just adverse events},
journal = {Surgical Neurology International},
year = {2026},
volume = {17},
pages = {338},
doi = {10.25259/sni_593_2026}
}
EUVIMED