EUVIMEDEUVIMED entdecken
Open Access

Manufacturer and User Facility Device Experience (MAUDE)-Dash: An open-source, interactive dashboard for real-time post-market surveillance of medical devices

Mokshal H Porwal

Surgical Neurology International · 15.05.2026 · 17 · 289

DOI: 10.25259/sni_201_2026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Surgical Neurology International, online erschienen am 15.05.2026. Verfasst von Mokshal H Porwal. Beteiligte Einrichtung: Department of Neurosurgery, Allegheny Health Network, Pittsburgh, PA, United States. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The Manufacturer and User Facility Device Experience (MAUDE) database is a cornerstone of post-market medical device surveillance in the United States, yet its large size, heterogeneous formats, and complex relational structure make it difficult for clinicians and researchers without advanced programming skills to use. This study describes the design and implementation of MAUDE-Dash, an open-source, interactive dashboard that streamlines the ingestion, management, and analysis of MAUDE data.

Methods

MAUDE-Dash utilizes a two-layer Python-based architecture. A dedicated ingestion pipeline normalizes and loads the public MAUDE text files into a single, efficient analytical database built on DuckDB. A Streamlit web application provides accessible modules for filtering reports, computing key performance indicators, visualizing temporal trends, characterizing patient demographics, interpreting device and patient problem codes, and performing narrative text analysis.

Results

In a demonstration use case involving pedicle screw systems, MAUDE-Dash rapidly identified thousands of relevant reports from 2018 to 2023. The dashboard enabled interactive exploration of yearly report volumes, distributions of event types, predominant manufacturers, common problem codes, and recurrent narrative terms (e.g., screw fracture, loosening). The complete analytic workflow, from query definition to denormalized dataset export, was achieved within minutes, significantly reducing technical barriers and analytic time compared to traditional methods.

Conclusion

MAUDE-Dash operationalizes an efficient, reproducible framework for post-market surveillance. By integrating an optimized local database with an accessible, modular interface, it democratizes large-scale signal exploration and hypothesis generation, providing an extensible platform for advanced safety analyses.

Schlagwörter

Stichwörter der Autor:innen

ComplicationManufacturer and user facility device experiencePedicle screwsSafetySurveillance

Autor:innen und Institutionen

  • Department of Neurosurgery, Allegheny Health Network, Pittsburgh, PA, United States.

Zitieren

APA

Porwal, M. H. (2026). Manufacturer and User Facility Device Experience (MAUDE)-Dash: An open-source, interactive dashboard for real-time post-market surveillance of medical devices. Surgical Neurology International, 17, 289. https://doi.org/10.25259/sni_201_2026

Vancouver

Porwal MH. Manufacturer and User Facility Device Experience (MAUDE)-Dash: An open-source, interactive dashboard for real-time post-market surveillance of medical devices. Surgical Neurology International. 2026;17:289. doi:10.25259/sni_201_2026

BibTeX
@article{Porwal2026,
  author = {Porwal, Mokshal H},
  title = {Manufacturer and User Facility Device Experience (MAUDE)-Dash: An open-source, interactive dashboard for real-time post-market surveillance of medical devices},
  journal = {Surgical Neurology International},
  year = {2026},
  volume = {17},
  pages = {289},
  doi = {10.25259/sni_201_2026}
}
Kostenlos starten →