Accuracy of catheter placement in ventriculoperitoneal shunt surgery with optical navigation: A retrospective comparative study
Surgical Neurology International · 27.03.2026 · 17 · 186
DOI: 10.25259/sni_1253_2025 ↗Kurz gefasst
Fachartikel in der Zeitschrift Surgical Neurology International, online erschienen am 27.03.2026. Verfasst von Yuzaburo Shimizu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Juntendo University Faculty of Medicine, Bunkyo, Tokyo, Japan. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Ventriculoperitoneal (VP) shunt surgery is the standard procedure for managing hydrocephalus. This study retrospectively compared catheter placement accuracy and clinical utility in VP shunt surgery using an optical navigation system versus freehand techniques.
Methods
This study retrospectively included patients from Juntendo University Hospital (January 2015 to March 2025). Only cases with postoperative computed tomography (CT) within 7 days were analyzed. Patients were divided into navigation-assisted and freehand groups. Catheter tip position was classified into four CT-based grades. Statistical comparisons used the Mann–Whitney U test and Fisher’s exact test.
Results
Forty-two patients (mean age 48.3 ± 25.5 years; 24 males [57.1%]) were analyzed. The navigation-assisted and freehand groups each comprised 21 patients. There were no significant intergroup differences in age (54.8 ± 21.2 vs. 41.7 ± 28.2 years, P = 0.16), sex ratio (62.5% vs. 37.5% male, P = 0.12), or median operative time (60 vs. 62 min, P = 0.98). Postoperative CT revealed that all cases in the navigation-assisted group achieved grade 1 placement (100%), whereas in the freehand group, 16 (76.2%) were grade 1, 3 (14.3%) were grade 2, and 2 (9.5%) were grade 3. Malposition (grades 2–4) occurred only in the freehand group (23.8%), with a significant difference between the groups ( P < 0.05).
Conclusion
In this limited retrospective series, optical navigation-assisted VP shunt surgery appeared to improve the accuracy of ventricular catheter placement compared with the freehand technique. Larger prospective studies are required to determine whether this improved accuracy translates into better long-term clinical outcomes.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, Juntendo University Faculty of Medicine, Bunkyo, Tokyo, Japan.
Zitieren
APA
Shimizu, Y., Akiyama, O., Kodama, T., Miyahara, R., & Kondo, A. (2026). Accuracy of catheter placement in ventriculoperitoneal shunt surgery with optical navigation: A retrospective comparative study. Surgical Neurology International, 17, 186. https://doi.org/10.25259/sni_1253_2025
Vancouver
Shimizu Y, Akiyama O, Kodama T, Miyahara R, Kondo A. Accuracy of catheter placement in ventriculoperitoneal shunt surgery with optical navigation: A retrospective comparative study. Surgical Neurology International. 2026;17:186. doi:10.25259/sni_1253_2025
BibTeX
@article{Shimizu2026,
author = {Shimizu, Yuzaburo and Akiyama, Osamu and Kodama, Takuma and Miyahara, Ryo and Kondo, Akihide},
title = {Accuracy of catheter placement in ventriculoperitoneal shunt surgery with optical navigation: A retrospective comparative study},
journal = {Surgical Neurology International},
year = {2026},
volume = {17},
pages = {186},
doi = {10.25259/sni_1253_2025}
}
EUVIMED