Circadian profile of 24-hour ambulatory blood pressure monitoring in healthy young adults
The National Medical Journal of India · 16.05.2026 · 39 · 218-223
DOI: 10.25259/nmji_617_2023 ↗Kurz gefasst
Fachartikel in der Zeitschrift The National Medical Journal of India, online erschienen am 16.05.2026. Verfasst von Arun Goel und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India. Hauptthemen laut MEDLINE: Blood Pressure Monitoring, Ambulatory, Circadian Rhythm, Blood Pressure. Die Arbeit nennt 40 Literaturangaben.
Abstract (Originalsprache)
Background
Hypertension is a major global threat associated with adverse cardiovascular events, especially in the Asian population. Ambulatory blood pressure monitoring (ABPM) is a valuable tool in diagnosis and management of hypertension and is predictive of future cardiovascular events. We assessed the feasibility of ABPM and generated preliminary normative data specific to the Indian population.
Methods
The circadian profile of 24-hour blood pressure (BP) in 53 healthy subjects was studied in their natural settings. Various circadian parameters like midline estimating statistic of rhythms (MESOR), 24-hour average BP, awake hours average BP, sleep hours average BP, % dip in systolic BP, and morning surge in BP were studied.
Results
BP and heart rate followed a sinusoidal pattern, with almost all the subjects having significant Cosinor rhythm. ABPM was generally well-tolerated, with no major discomfort, limited restrictions on daily activities, and the values of ABPM parameters in this population matched those of other populations.
Conclusion
ABPM is feasible and acceptable in India and follows a sinusoidal pattern in healthy young adults, similar to other populations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Physiology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India.
- Department of Physiology, All India Institute of Medical Sciences, Bhubaneswar, Odisha, India.
- Department of Physiology, King George's Medical University (KGMU), Lucknow, Uttar Pradesh, India.
- Department of Physiology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India.
Zitieren
APA
Goel, A., Goyal, M., Mahadule, A., Verma, N., & Tiwari, S. (2026). Circadian profile of 24-hour ambulatory blood pressure monitoring in healthy young adults. The National Medical Journal of India, 39, 218-223. https://doi.org/10.25259/nmji_617_2023
Vancouver
Goel A, Goyal M, Mahadule A, Verma N, Tiwari S. Circadian profile of 24-hour ambulatory blood pressure monitoring in healthy young adults. The National Medical Journal of India. 2026;39:218-223. doi:10.25259/nmji_617_2023
BibTeX
@article{Goel2026,
author = {Goel, Arun and Goyal, Manish and Mahadule, Ashwini and Verma, Narsingh and Tiwari, Sunita},
title = {Circadian profile of 24-hour ambulatory blood pressure monitoring in healthy young adults},
journal = {The National Medical Journal of India},
year = {2026},
volume = {39},
pages = {218--223},
doi = {10.25259/nmji_617_2023}
}
EUVIMED