Artificial intelligence-based automated sleep staging using heart rate variability: Assessment of performance and clinical prospects

Suvradeep Chakraborty, Manish Goyal, Paritosh Goyal, Priyadarshini Mishra

The National Medical Journal of India · 08.06.2026 · 39 · 224-230

DOI: 10.25259/nmji_397_2024 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The National Medical Journal of India, online erschienen am 08.06.2026. Verfasst von Suvradeep Chakraborty und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Nil Ratan Sircar Medical College and Hospital, Kolkata, West Bengal, India. Hauptthemen laut MEDLINE: Artificial Intelligence, Heart Rate, Intelligent Systems, Sleep Stages. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 66 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Some artificial intelligence models use heart rate variability (HRV) features to classify sleep stages. Estimation of HRV indices requires the removal of outliers and correction of ectopic beats from the electrocardiography (ECG) data. In addition, sleep epochs bear a temporal relationship to each other, while classifiers treat epochs as independent entities. To address this, we propose a bidirectional long short-term (BLSTM) architecture and a random forest classifier (RFC) for the classification of 5 sleep stages, using HRV features and sleep epoch index.

Methods

Polysomnography data of 645 subjects from the ‘You Snooze You Win: The PhysioNet/Computing in Cardiology Challenge 2018’ dataset were selected. ECG data were corrected for outliers and ectopic beats using linear interpolation. Time, frequency, and non-linear domains’ HRV indices were determined and fed into the models.

Results

The RFC and BLSTM models obtained validation classification accuracy of 79.6 (1.6) and 74.70 (1.05), respectively, with RFC outperforming BLSTM. Further, the RFC model was validated with polysomnography data of 43 subjects from the Haaglanden Medisch Centrum dataset and obtained an accuracy of 78.9% with Cohen’s kappa of 0.70 and macro F1 score of 0.789. We also demonstrated the importance of a proper pre-processing pipeline and incorporating the epoch index as a temporal feature for training the classification model.

Conclusion

Automated analysis of sleep data from diverse centres has potential to provide insights into population-wide sleep patterns and disease stratification, enabling targeted interventions and public health education.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceHeart RateIntelligent SystemsSleep StagesAdultFemaleHumansMaleClassification AlgorithmsElectrocardiographyPolysomnographyRandom Forest

Autor:innen und Institutionen

  • Department of Radiation Oncology, Nil Ratan Sircar Medical College and Hospital, Kolkata, West Bengal, India.
  • Department of Physiology, All India Institute of Medical Sciences, Bhubaneswar, Odisha, India.
  • Department of Computing Science, University of Alberta, Edmonton, Alberta, Canada.

Zitieren

APA

Chakraborty, S., Goyal, M., Goyal, P., & Mishra, P. (2026). Artificial intelligence-based automated sleep staging using heart rate variability: Assessment of performance and clinical prospects. The National Medical Journal of India, 39, 224-230. https://doi.org/10.25259/nmji_397_2024

Vancouver

Chakraborty S, Goyal M, Goyal P, Mishra P. Artificial intelligence-based automated sleep staging using heart rate variability: Assessment of performance and clinical prospects. The National Medical Journal of India. 2026;39:224-230. doi:10.25259/nmji_397_2024

BibTeX
@article{Chakraborty2026,
  author = {Chakraborty, Suvradeep and Goyal, Manish and Goyal, Paritosh and Mishra, Priyadarshini},
  title = {Artificial intelligence-based automated sleep staging using heart rate variability: Assessment of performance and clinical prospects},
  journal = {The National Medical Journal of India},
  year = {2026},
  volume = {39},
  pages = {224--230},
  doi = {10.25259/nmji_397_2024}
}
Kostenlos starten →