EUVIMEDEUVIMED entdecken
VergleichsstudieFallbericht

Reduced iodine solution as an objective indicator of tissue perfusion during embalming in cadavers

Surraj Susai, Mrudula Chandrupatla, Punnapa Raviteja

The National Medical Journal of India · 20.05.2026 · 39 · 309-311

DOI: 10.25259/nmji_1402_2024 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The National Medical Journal of India, online erschienen am 20.05.2026. Verfasst von Surraj Susai und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anatomy, All India Institute of Medical Sciences, Bibinagar, Hyderabad, Telangana, India. Hauptthemen laut MEDLINE: Embalming, Perfusion. Die Arbeit nennt 9 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Anatomists rely on subjective cadaveric signs such as frothy ooze or abdominal fullness to mark the completion of tissue perfusion during embalming. We evaluated the use of a reduced iodide solution, coated over certain distinct sites on cadavers, to mark the completion of formalin perfusion to stop embalming at the right time.

Methods

In a comparative study, reduced iodide was coated over the nail plates of the great toes and onto sticks inserted into the pinnae prior to the start of embalming of 6 cadavers while another set of 6 cadavers underwent standard embalming. A fixed amount (8 L) of embalming solution was prepared for each cadaver. In the first 6 cadavers, embalming fluid infusion was stopped when the colour changed from brownish yellow to colourless while in the controls, embalming fluid was infused till standard signs of completion were reached. The volume of unused embalming fluid in the two sets of cadavers was compared.

Results

The amount of unused embalming fluid was significantly higher in the experimental set of cadavers [3616.66 (0.76) ml v. 1783.33 (0.64) ml] when compared with the control set while the infusion time was significantly lower [373.33 (0.67) minutes v. 623.33 (0.69) minutes].

Conclusion

Use of the reduced iodide method to objectively assess completion of embalming could result in saving time and the amount of formalin used during the embalming procedure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EmbalmingPerfusionHumansCadaverFormaldehyde

Substanzen

Formaldehyde

Autor:innen und Institutionen

  • Department of Anatomy, All India Institute of Medical Sciences, Bibinagar, Hyderabad, Telangana, India.

Zitieren

APA

Susai, S., Chandrupatla, M., & Raviteja, P. (2026). Reduced iodine solution as an objective indicator of tissue perfusion during embalming in cadavers. The National Medical Journal of India, 39, 309-311. https://doi.org/10.25259/nmji_1402_2024

Vancouver

Susai S, Chandrupatla M, Raviteja P. Reduced iodine solution as an objective indicator of tissue perfusion during embalming in cadavers. The National Medical Journal of India. 2026;39:309-311. doi:10.25259/nmji_1402_2024

BibTeX
@article{Susai2026,
  author = {Susai, Surraj and Chandrupatla, Mrudula and Raviteja, Punnapa},
  title = {Reduced iodine solution as an objective indicator of tissue perfusion during embalming in cadavers},
  journal = {The National Medical Journal of India},
  year = {2026},
  volume = {39},
  pages = {309--311},
  doi = {10.25259/nmji_1402_2024}
}
Kostenlos starten →