Factors associated with short and mid-term compliance to continuous positive airway pressure in obstructive sleep apnea
Journal of the Pan African Thoracic Society · 13.05.2026 · 7 · 18-26
DOI: 10.25259/jpats_6_2026 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the Pan African Thoracic Society, online erschienen am 13.05.2026. Verfasst von Virginie Poka-Mayap und 4 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben.
Abstract (Originalsprache)
Objectives
Compliance with continuous positive airway pressure (CPAP) therapy determines the outcome of the management of obstructive sleep apnea (OSA) syndrome. The aim of the study was to examine a large panel of variables measured before CPAP therapy in OSA patients, in an attempt to identify factors associated with CPAP compliance. Materials and Methods: In this retrospective cohort study, socio-demographic, psychometric, clinical, and polysomnographic (diagnostic and CPAP titration nights) variables were collected in moderate to severe OSA patients who started on CPAP therapy at home. Compliance was assessed at the 4 th and 16 th months of follow-up. Logistic regression was used to identify factors associated with poor compliance, according to different thresholds (4 h and 4 h + 70% of nights use, 5 h and 6 h).
Results
After 4 months, patients ( n = 261) used their machine a median (25 th –75 th percentiles) of 85% (57–97) of days, while the median daily effective use was 4.4 (2.6–6.2) h. Factors associated with poor compliance were non-Caucasian ethnicity (all thresholds), no improvement in slow wave sleep (SWS) percentage during CPAP titration (compliance thresholds of 4 h and 4 h + 70% of nights’ use), and subjective poor quality of sleep (compliance thresholds of 5 h and 6 h).
Conclusion
CPAP compliance is associated to some extent with the baseline features. Non-Caucasian patients and patients with a lack of improvement in SWS at titration or with poor sleep quality are at risk of poor compliance and could benefit from an intensive follow-up aiming to enhance compliance.
Zitieren
APA
Poka-Mayap, V., Balkissou, A. D., Massongo, M., Pefura-Yone, E. W., & Noseda, A. (2026). Factors associated with short and mid-term compliance to continuous positive airway pressure in obstructive sleep apnea. Journal of the Pan African Thoracic Society, 7, 18-26. https://doi.org/10.25259/jpats_6_2026
Vancouver
Poka-Mayap V, Balkissou AD, Massongo M, Pefura-Yone EW, Noseda A. Factors associated with short and mid-term compliance to continuous positive airway pressure in obstructive sleep apnea. Journal of the Pan African Thoracic Society. 2026;7:18-26. doi:10.25259/jpats_6_2026
BibTeX
@article{PokaMayap2026,
author = {Poka-Mayap, Virginie and Balkissou, Adamou Dodo and Massongo, Massongo and Pefura-Yone, Eric Walter and Noseda, Andre},
title = {Factors associated with short and mid-term compliance to continuous positive airway pressure in obstructive sleep apnea},
journal = {Journal of the Pan African Thoracic Society},
year = {2026},
volume = {7},
pages = {18--26},
doi = {10.25259/jpats_6_2026}
}
EUVIMED