Oxidized Regenerated Cellulose Powder Is Associated with Less Swelling and Early Pain After Computer-Assisted Total Knee Arthroplasty
Journal of Orthopaedics · 20.11.2026 · 80 · 16-24
DOI: 10.25259/joo_93_2026 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopaedics, online erschienen am 20.11.2026. Verfasst von Ryota Yamagami und 5 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
Objectives
Postoperative swelling persists after total knee arthroplasty (TKA) despite tranexamic acid and may worsen early pain. We evaluated whether adjunctive oxidized regenerated cellulose (ORC) powder use was associated with lower computed tomography-based localized swelling at 2 weeks and lower early postoperative pain after computer-assisted TKA. Material and Methods: In this retrospective cohort study, primary computer-assisted TKAs with ORC powder were compared with historical controls without ORC. After 1:1 propensity score matching, 58 pairs were analyzed. Primary outcomes were pain from postoperative day 0 to 14 and the postoperative-to-preoperative cross-sectional area ratio on computed tomography at 2 weeks. Secondary outcomes included blood-loss variables and early knee range of motion.
Results
The cross-sectional area ratio was lower with ORC (1.08 ± 0.08 vs 1.13 ± 0.07; mean difference, −0.042; 95% confidence interval, −0.069 to −0.014; p = 0.003). Pain trajectories differed between groups (group-by-time interaction, p = 0.002), with lower pain scores on postoperative day (POD) 2–5 after Holm adjustment (mean differences 1.0-1.3 points; all adjusted p < 0.05). Estimated total blood loss was similar, whereas hidden blood loss was lower (674.2 ± 319.8 vs 794.5 ± 323.4 mL, p = 0.046) and the hemoglobin decrease on POD 7 was smaller (2.2 ± 1.1 vs 2.6 ± 1.0 g/dL, p = 0.041). Flexion loss was smaller at PODs 7 and 14 ( p = 0.049 and 0.013).
Conclusion
In tranexamic acid-managed computer-assisted TKA, adjunctive ORC powder use was associated with modestly lower localized swelling and pain during POD 2–5, less hidden blood loss, and slightly better early flexion recovery. These historical-control findings do not establish causality, safety for uncommon complications, or a basis for routine use.
Zitieren
APA
Yamagami, R., Kono, K., Kawaguchi, K., Kobayashi, T., Taketomi, S., & Tanaka, S. (2026). Oxidized Regenerated Cellulose Powder Is Associated with Less Swelling and Early Pain After Computer-Assisted Total Knee Arthroplasty. Journal of Orthopaedics, 80, 16-24. https://doi.org/10.25259/joo_93_2026
Vancouver
Yamagami R, Kono K, Kawaguchi K, Kobayashi T, Taketomi S, Tanaka S. Oxidized Regenerated Cellulose Powder Is Associated with Less Swelling and Early Pain After Computer-Assisted Total Knee Arthroplasty. Journal of Orthopaedics. 2026;80:16-24. doi:10.25259/joo_93_2026
BibTeX
@article{Yamagami2026,
author = {Yamagami, Ryota and Kono, Kenichi and Kawaguchi, Kohei and Kobayashi, Takashi and Taketomi, Shuji and Tanaka, Sakae},
title = {Oxidized Regenerated Cellulose Powder Is Associated with Less Swelling and Early Pain After Computer-Assisted Total Knee Arthroplasty},
journal = {Journal of Orthopaedics},
year = {2026},
volume = {80},
pages = {16--24},
doi = {10.25259/joo_93_2026}
}
EUVIMED