Does Robotic Assistance Improve Restoration of Coronal Plane Alignment of the Knee in Kinematically Aligned Total Knee Arthroplasty? A Comparative Alignment Study
Journal of Orthopaedics · 31.08.2026 · 78 · 84-90
DOI: 10.25259/joo_91_2026 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopaedics, online erschienen am 31.08.2026. Verfasst von Jeremy Tze En Lim und 7 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
Objectives
To compare Coronal Plane Alignment of the Knee (CPAK) phenotype restoration and component alignment accuracy between robotic-assisted and conventional calipered kinematically aligned total knee arthroplasty (KA-TKA). Material and Methods: A retrospective comparative study of 319 primary KA-TKAs (127 robotic, 192 conventional) performed between 2020 and 2024 was conducted. Pre- and six-week postoperative weight-bearing long-leg radiographs were used to determine arithmetic hip–knee–ankle angle (aHKA), joint-line obliquity (JLO), and CPAK phenotype. CPAK transitions were classified as restoration, aHKA-driven change, JLO-driven change, or non-favorable shift. Alignment accuracy of the femoral component (lateral distal femoral angle, LDFA) and tibial component (medial proximal tibial angle, MPTA) within ±3° of the target was compared.
Results
Baseline characteristics were comparable between groups, apart from slightly higher age in the robotic cohort. CPAK restoration rates were similar (52.6% vs 52.8%, p = 1.000). aHKA-driven changes occurred in 30.2% versus 22.0% ( p = 0.447), while JLO-driven changes were less frequent in the robotic group (15.1% vs 24.4%, p = 0.053). Robotic assistance improved tibial alignment accuracy (80.3% vs 68.2%, p = 0.024), whereas femoral alignment accuracy was similar (85.0% vs 83.9%, p = 0.898).
Conclusion
Robotic KA-TKA improved tibial alignment precision and reduced joint-line obliquity deviation but did not increase CPAK phenotype restoration compared with conventional KA-TKA. These findings suggest that coronal phenotype preservation depends on combined femoral–tibial alignment rather than isolated component accuracy.
Zitieren
APA
Lim, J. T. E., Ng, Y., Chen, J. W., Kow, R. Y., Pang, H. N., Tay, D. K. J., Yeo, S. J., & Liow, M. H. L. (2026). Does Robotic Assistance Improve Restoration of Coronal Plane Alignment of the Knee in Kinematically Aligned Total Knee Arthroplasty? A Comparative Alignment Study. Journal of Orthopaedics, 78, 84-90. https://doi.org/10.25259/joo_91_2026
Vancouver
Lim JTE, Ng Y, Chen JW, Kow RY, Pang HN, Tay DKJ, et al. Does Robotic Assistance Improve Restoration of Coronal Plane Alignment of the Knee in Kinematically Aligned Total Knee Arthroplasty? A Comparative Alignment Study. Journal of Orthopaedics. 2026;78:84-90. doi:10.25259/joo_91_2026
BibTeX
@article{Lim2026,
author = {Lim, Jeremy Tze En and Ng, Yong and Chen, Jia Wei and Kow, Ren Yi and Pang, Hee Nee and Tay, Darren Keng Jin and Yeo, Seng Jin and Liow, Ming Han Lincoln},
title = {Does Robotic Assistance Improve Restoration of Coronal Plane Alignment of the Knee in Kinematically Aligned Total Knee Arthroplasty? A Comparative Alignment Study},
journal = {Journal of Orthopaedics},
year = {2026},
volume = {78},
pages = {84--90},
doi = {10.25259/joo_91_2026}
}
EUVIMED