EUVIMEDEUVIMED entdecken
Crossref

Evaluation of analytical reliability based on variance index score, measurement uncertainty and root cause analysis in a 2-year external quality assessment scheme

Dharmikkumar Savjibhai Patel, Afsana Ahemadhusen Bloch, Deepakji Ranguji Thakor, Nikita Dharmik Patel

Journal of Laboratory Physicians · 14.08.2026 · 18 · 440-449

DOI: 10.25259/jlp_43_2026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Laboratory Physicians, online erschienen am 14.08.2026. Verfasst von Dharmikkumar Savjibhai Patel und 3 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate analytical performance in a clinical biochemistry laboratory using an integrated approach combining variance index score (VIS), measurement uncertainty (MU), target score and root cause analysis (RCA) based on external quality assessment scheme (EQAS) data. Materials and Methods: This retrospective analytical study evaluated EQAS results generated over 2 years (January 2022 to December 2023) in a National Accreditation Board for Testing and Calibration Laboratories-accredited tertiary-care clinical biochemistry laboratory. A total of 1,853 EQAS results covering 68 analytical parameters were analysed across multiple platforms and programmes, including Bio-Rad EQAS, Randox International Quality Assessment Scheme and the Quality Assurance Forum. Analytical performance was assessed using VIS, target score for immunoassays, MU estimated by the Nordtest top-down approach and structured RCA for EQAS outliers. Statistical analysis: Descriptive statistics were applied. VIS, target score and MU were expressed as means with minimum and maximum values. EQAS outliers were reported as counts and percentages, and RCA findings were categorised by phase of error.

Results

Of the 1,853 EQAS results analysed, 96.4% were within acceptable limits. Sixty-seven outliers (3.61%) were identified. Most deviations originated in the analytical phase (79.1%), followed by pre-analytical causes, while no post-analytical errors were observed. Routine chemistry, electrolyte and immunoassay parameters demonstrated predominantly good to excellent VIS and MU performance. Parathyroid hormone showed persistently high VIS and MU values, indicating analytical bias.

Conclusions

The synthesis of VISs, MU, target scores and structured RCA offers a comprehensive framework for evaluating EQAS. Integrating these quality indicators streamlines the identification of analytical deviations, guides targeted corrective and preventive interventions and reinforces analytical reliability and continuous quality improvement within clinical biochemistry laboratories.

Zitieren

APA

Patel, D. S., Bloch, A. A., Thakor, D. R., & Patel, N. D. (2026). Evaluation of analytical reliability based on variance index score, measurement uncertainty and root cause analysis in a 2-year external quality assessment scheme. Journal of Laboratory Physicians, 18, 440-449. https://doi.org/10.25259/jlp_43_2026

Vancouver

Patel DS, Bloch AA, Thakor DR, Patel ND. Evaluation of analytical reliability based on variance index score, measurement uncertainty and root cause analysis in a 2-year external quality assessment scheme. Journal of Laboratory Physicians. 2026;18:440-449. doi:10.25259/jlp_43_2026

BibTeX
@article{Patel2026,
  author = {Patel, Dharmikkumar Savjibhai and Bloch, Afsana Ahemadhusen and Thakor, Deepakji Ranguji and Patel, Nikita Dharmik},
  title = {Evaluation of analytical reliability based on variance index score, measurement uncertainty and root cause analysis in a 2-year external quality assessment scheme},
  journal = {Journal of Laboratory Physicians},
  year = {2026},
  volume = {18},
  pages = {440--449},
  doi = {10.25259/jlp_43_2026}
}
Kostenlos starten →