Detections of Chemicals and Migratory Plastics in Peritoneal Dialysis Fluids
Indian Journal of Nephrology · 01.07.2024 · 35 · 34-39
DOI: 10.25259/ijn_515_23 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indian Journal of Nephrology, online erschienen am 01.07.2024. Verfasst von Sanjay Kumar Panda und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nephrology, Base Hospital Delhi Cantt, New Delhi, India. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Peritoneal dialysis (PD) is an important modality of renal replacement therapy (RRT). Peritonitis and ultrafiltration failure are complications that have a long-term impact on PD patients. Besides touch contamination, procedural errors and clinical reasons of peritonitis, contaminants, and constituents of peritoneal dialysis fluids (PDFs) have been implicated in causing peritonitis and ultrafiltration failure. This study was aimed to test the PDFs in India for the presence of migratory plastics. Materials and Methods: PDFs from the two manufacturers in India were tested using liquid chromatography mass spectrometry (LCMS) and gas chromatography mass spectrometry (GCMS) with headspace analysis (volatile compounds) and pyrolysis of plastics (polymer compounds). The storage conditions and handling were uniform.
Results
The results revealed impurities of acetate compounds and aldehyde derivatives of glucose degradation products (GDPs) with contaminants and leachable plastics. There were high levels of GDP derivative in the form of 5-hydroxymethylfurfural compounds (5-HMF). The analysis revealed the presence of plastic softeners in very high concentrations.
Conclusion
The study unmasks the presence of chemicals and GDPs that can be implicated in pathogenesis of sterile peritonitis and ultrafiltration failure. The study demonstrated the presence of leachable plastics. In conclusion, LCMS and GCMS studies can be used to test PDFs for unwanted chemicals prior to human use.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Nephrology, Base Hospital Delhi Cantt, New Delhi, India.
- Department of Analytical and Structural Chemistry, CSIR-Indian Institute of Chemical Technology, Hyderabad, Tarnaka, India.
- Department of Chemical Engineering, Indian Institute of Technology, Hyderabad, Tarnaka, India.
Zitieren
APA
Panda, S. K., Maloth, R. K., Upadyayalu, V., Mishra, A., & Noronha, S. (2024). Detections of Chemicals and Migratory Plastics in Peritoneal Dialysis Fluids. Indian Journal of Nephrology, 35, 34-39. https://doi.org/10.25259/ijn_515_23
Vancouver
Panda SK, Maloth RK, Upadyayalu V, Mishra A, Noronha S. Detections of Chemicals and Migratory Plastics in Peritoneal Dialysis Fluids. Indian Journal of Nephrology. 2024;35:34-39. doi:10.25259/ijn_515_23
BibTeX
@article{Panda2024,
author = {Panda, Sanjay Kumar and Maloth, Rama Krishna and Upadyayalu, Vijayasarthi and Mishra, Ankita and Noronha, Santosh},
title = {Detections of Chemicals and Migratory Plastics in Peritoneal Dialysis Fluids},
journal = {Indian Journal of Nephrology},
year = {2024},
volume = {35},
pages = {34--39},
doi = {10.25259/ijn_515_23}
}
EUVIMED