Querschnittstudie in der Zeitschrift The Indian Journal of Medical Research, 2026. Verfasst von Subha Palanikumarasamy und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Transfusion Medicine, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India. Hauptthemen laut MEDLINE: Isoantibodies, Blood Group Antigens, Blood Grouping and Crossmatching, Transfusion Reaction. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and objectives Minor blood group antigens (apart from ABO) can cause haemolytic transfusion reaction in patients who need multiple transfusions. Antibodies against these antigens are typically detected using commercial cell panels. Developing indigenous panels ensures the potential for inclusion of population-specific antigens. We aimed to develop and validate in-house antibody cell panels to detect antibodies against minor blood group antigens and compare it with commercial panel.

Methods

A cross-sectional study was conducted between July 2022 and December 2023 among 3000 voluntary blood donors. Participants with ‘O’ blood group who were direct antiglobulin test negative and transfusion-transmitted infection non-reactive underwent phenotyping for low-prevalence antigens (E, K, In a , C w ). Extended phenotyping was performed for individuals positive for these antigens. Based on selected antigens corresponding to commonly encountered clinically significant alloantibodies, in-house panels were developed and validated using known antibody-positive and antibody-negative samples, and their diagnostic performance was evaluated against a commercial panel.

Results

Of the 3,000 participants, 700 belonged to ‘O’ blood group. The prevalence of E, K, In a , and C w positivity was 105 (15%), 17 (2.4%), 15 (2.1%), and 10 (1.4%), respectively. A 4- and a 12-cell panel were developed for screening and identification, respectively, from 16 participants. The sensitivity and specificity of in-house panel were 100% [95% Confidence interval (CI): 91.2–100%], and 100% (95% CI: 98.6–100%), respectively when validated with commercial cell panel. The annual cost for a commercial cell panel was INR (₹) ₹1,04,800, while in-house panel’s one-time cost was ₹55,760 with recurring cost of ₹1,440 every three months. Interpretation and conclusions The in-house antibody cell panel demonstrated comparable diagnostic performance to the commercial panel, with complete concordance, along with lower cost.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IsoantibodiesBlood Group AntigensBlood Grouping and CrossmatchingTransfusion ReactionHumansTertiary Care CentersCross-Sectional StudiesFemaleProspective StudiesMaleABO Blood-Group SystemBlood DonorsAdult

Stichwörter der Autor:innen

Antibody screeningDiagnostic accuracyIndiaMinor blood group antigensPhenotyping

Substanzen

IsoantibodiesBlood Group AntigensABO Blood-Group System

Autor:innen und Institutionen

  • Department of Transfusion Medicine, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India.
  • Department of Community Medicine and Family Medicine, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India.
  • Department of Transfusion Medicine, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala, India.
  • Department of Pathology and Lab medicine, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India.

Zitieren

APA

Palanikumarasamy, S., Harsh, G., Shanmugasundaram, S., Saravanan, S., Arun, M., Gowtham, P. S., Mittal, S., Gupta, A., Elhence, P., & Bajpayee, A. (2026). Characterisation, development, and validation of an in-house antibody cell panel: A prospective cross-sectional study from a tertiary care hospital. The Indian Journal of Medical Research. https://doi.org/10.25259/ijmr_3729_2025

Vancouver

Palanikumarasamy S, Harsh G, Shanmugasundaram S, Saravanan S, Arun M, Gowtham PS, et al. Characterisation, development, and validation of an in-house antibody cell panel: A prospective cross-sectional study from a tertiary care hospital. The Indian Journal of Medical Research. 2026. doi:10.25259/ijmr_3729_2025

BibTeX
@article{Palanikumarasamy2026,
  author = {Palanikumarasamy, Subha and Harsh, Gautam and Shanmugasundaram, Suseendar and Saravanan, Sathish and Arun, M and Gowtham, P S and Mittal, Siddharth and Gupta, Anubhav and Elhence, Poonam and Bajpayee, Archana},
  title = {Characterisation, development, and validation of an in-house antibody cell panel: A prospective cross-sectional study from a tertiary care hospital},
  journal = {The Indian Journal of Medical Research},
  year = {2026},
  doi = {10.25259/ijmr_3729_2025}
}
Kostenlos starten →