EUVIMEDEUVIMED entdecken
Crossref

Preserving the precious: Use of segment drawn at the time of preparation for routine quality control of fresh frozen plasma

Charumathy Arjunan, Dheeraj Khetan, Atul Priyadarshi, Anupam Verma, Rajendra Chaudhary, Priti Elhence, Anup Kumar, Sachin Kumar

Indian Journal of Medical Research · 05.11.2026 · 1-8

DOI: 10.25259/ijmr_367_2026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Medical Research, online erschienen am 05.11.2026. Verfasst von Charumathy Arjunan und 7 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and objectives Quality control testing of fresh frozen plasma (FFP) requires estimation of unit volume, factor VIII levels, fibrinogen levels, and sterility testing. Sampling from the FFP unit requires thawing of the unit leading to its discard. We investigated if sample taken from segment instead of plasma unit can be used for quality control testing to preserve the plasma unit.

Methods

Cross-sectional study involving 35 FFP units prepared from 450 mL whole blood donations. Segments (∼10 cm) of plasma units were prepared and stored alongside FFP unit. Prothrombin time (PT), activated partial thromboplastin time (APTT), factor V, factor VII, factor VIII, and fibrinogen levels were estimated using automated analyser (STA Satellite, Diagnostica Stago). Segment and bag values were compared (Wilcoxon signed rank test). Simple linear regression was used to derive a mathematical equation for variables with significant differences.

Results

PT (14.6 vs. 14.2 sec), factor VII activity (144.9 vs . 161.2%,) and fibrinogen levels (305.7 vs. 301.9 mg/dL) were comparable in both samples. Significant differences were observed in mean APTT (29.7 vs. 30.7 sec, P =0.04), mean factor VIII activity (216.2% vs. 172.6%, P =0.006) and mean factor V activity (132.3% vs. 104.4%, P =0.011) between the segment and bag samples. Mathematical equation for estimation of bag APTT and factor VIII values from the segment sample was derived using 70% of the sample and successfully validated with remaining 30% sample. Interpretation and conclusions With validated equations, for APTT and factor VIII, segment samples can reliably support routine plasma quality control, offering a practical way to reduce plasma discard.

Zitieren

APA

Arjunan, C., Khetan, D., Priyadarshi, A., Verma, A., Chaudhary, R., Elhence, P., Kumar, A., & Kumar, S. (2026). Preserving the precious: Use of segment drawn at the time of preparation for routine quality control of fresh frozen plasma. Indian Journal of Medical Research, 0, 1-8. https://doi.org/10.25259/ijmr_367_2026

Vancouver

Arjunan C, Khetan D, Priyadarshi A, Verma A, Chaudhary R, Elhence P, et al. Preserving the precious: Use of segment drawn at the time of preparation for routine quality control of fresh frozen plasma. Indian Journal of Medical Research. 2026;0:1-8. doi:10.25259/ijmr_367_2026

BibTeX
@article{Arjunan2026,
  author = {Arjunan, Charumathy and Khetan, Dheeraj and Priyadarshi, Atul and Verma, Anupam and Chaudhary, Rajendra and Elhence, Priti and Kumar, Anup and Kumar, Sachin},
  title = {Preserving the precious: Use of segment drawn at the time of preparation for routine quality control of fresh frozen plasma},
  journal = {Indian Journal of Medical Research},
  year = {2026},
  volume = {0},
  pages = {1--8},
  doi = {10.25259/ijmr_367_2026}
}
Kostenlos starten →