Efficiency of imaging and frozen section in analysis of sentinel lymph node biopsy in early breast cancer
Indian Journal of Breast Imaging · 20.06.2026 · 4 · 19-24
DOI: 10.25259/ijbi_3_2026 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indian Journal of Breast Imaging, online erschienen am 20.06.2026. Verfasst von Sumitha Vinoth Kumar und 4 weiteren Autor:innen. Die Arbeit nennt 9 Literaturangaben.
Abstract (Originalsprache)
Objectives
A retrospective study on false negative sentinel lymph node biopsies that were positive on final histopathology with ultrasonography (USG) imaging, and positron emission tomography-computed tomography (PET/CT) correlation of the respective axillary lymph nodes. Materials and Methods: This is a retrospective study of frozen biopsy on the sentinel lymph node in a single center, which was carried out in 518 early breast cancer cases for a period of 5 years. Especially, false negative lymph nodes were included and compared with USG imaging and PET/CT reports.
Results
Out of 518 sentinel lymph node biopsies performed, 23 showed frozen and final histopathology discordance, resulting in false-negative cases in frozen section. Out of the 23 cases, the PET CT study revealed 5 faint FDG-avid, 13 non-FDG-avid, and 4 FDG-avid results. And in one case, PET CT was not done. Out of 23, 7 nodes showed eccentric cortical thickening on USG.
Conclusion
Intraoperative frozen section evaluation of sentinel lymph node biopsy in breast cancer enables more efficient and accurate axillary staging. The imaging modalities PET CT and USG identify suspicious lymph nodes and aid in the diagnosis of metastases, and therefore, A multimodal approach always has high diagnostic accuracy.
Zitieren
APA
Kumar, S. V., Govindarajan, N., Sivaramalingam, G. P., Shankarraman, D., & Krishna, S. R. (2026). Efficiency of imaging and frozen section in analysis of sentinel lymph node biopsy in early breast cancer. Indian Journal of Breast Imaging, 4, 19-24. https://doi.org/10.25259/ijbi_3_2026
Vancouver
Kumar SV, Govindarajan N, Sivaramalingam GP, Shankarraman D, Krishna SR. Efficiency of imaging and frozen section in analysis of sentinel lymph node biopsy in early breast cancer. Indian Journal of Breast Imaging. 2026;4:19-24. doi:10.25259/ijbi_3_2026
BibTeX
@article{Kumar2026,
author = {Kumar, Sumitha Vinoth and Govindarajan, Nandini and Sivaramalingam, Geetha Priya and Shankarraman, Debashri and Krishna, Selvi Radha},
title = {Efficiency of imaging and frozen section in analysis of sentinel lymph node biopsy in early breast cancer},
journal = {Indian Journal of Breast Imaging},
year = {2026},
volume = {4},
pages = {19--24},
doi = {10.25259/ijbi_3_2026}
}
EUVIMED