Surgical outcomes of sutureless, glueless intrascleral fixation of intraocular lenses: A prospective interventional study
Global Journal of Cataract Surgery and Research in Ophthalmology · 17.08.2026 · 1-6
DOI: 10.25259/gjcsro_7_2026 ↗Kurz gefasst
Fachartikel in der Zeitschrift Global Journal of Cataract Surgery and Research in Ophthalmology, online erschienen am 17.08.2026. Verfasst von Kiran Gagdasbhai Chaudhary und 3 weiteren Autor:innen. Die Arbeit nennt 12 Literaturangaben.
Abstract (Originalsprache)
Objectives
The objective of the study is to evaluate the visual outcomes and post-operative complications of sutureless, glueless intrascleral fixation of posterior chamber scleral fixated intraocular lenses (IOLs) using a modified 26-gauge needle-assisted haptic exteriorisation technique. Materials and Methods: This prospective interventional study included aphakic eyes or eyes with dislocated/subluxated lenses or IOLs undergoing pars plana vitrectomy with sutureless scleral fixation of a three-piece polymethyl methacrylate (PMMA) IOL. The three-piece PMMA IOL (Aurolab) was the preferred lens due to its cost-effectiveness and standard availability in the government hospital setup. All surgeries were performed by a single surgeon between June 2023 and June 2024. Best-corrected visual acuity (BCVA), intraocular pressure and post-operative complications were assessed on postoperative day 1, week 1, month 1, month 3 and month 6.
Results
A total of 50 eyes were included. The most common indications were aphakia following complicated cataract surgery and dislocated/subluxated IOLs. Mean BCVA improved significantly from pre-operative levels at final follow-up. Early post-operative complications included transient corneal oedema and mild hypotony, which resolved with conservative management. No haptic breakage was noted during implantation, although haptic bending occurred in a few cases. No cases of endophthalmitis or late dislocation were observed during the follow-up period.
Conclusion
Sutureless, glueless intrascleral fixation of IOL using a modified 26-gauge needle technique is a safe, effective and reproducible method for visual rehabilitation in eyes lacking capsular support. The technique avoids suture-related complications, provides good IOL stability and yields favourable visual outcomes. A common challenge encountered during the early learning phase was the technical difficulty of tucking the haptic into the scleral pocket.
Zitieren
APA
Chaudhary, K. G., Negi, P. S., Desai, N. K., & Aggarwal, S. (2026). Surgical outcomes of sutureless, glueless intrascleral fixation of intraocular lenses: A prospective interventional study. Global Journal of Cataract Surgery and Research in Ophthalmology, 0, 1-6. https://doi.org/10.25259/gjcsro_7_2026
Vancouver
Chaudhary KG, Negi PS, Desai NK, Aggarwal S. Surgical outcomes of sutureless, glueless intrascleral fixation of intraocular lenses: A prospective interventional study. Global Journal of Cataract Surgery and Research in Ophthalmology. 2026;0:1-6. doi:10.25259/gjcsro_7_2026
BibTeX
@article{Chaudhary2026,
author = {Chaudhary, Kiran Gagdasbhai and Negi, Puja Shubham and Desai, Neha Kantilal and Aggarwal, Somesh},
title = {Surgical outcomes of sutureless, glueless intrascleral fixation of intraocular lenses: A prospective interventional study},
journal = {Global Journal of Cataract Surgery and Research in Ophthalmology},
year = {2026},
volume = {0},
pages = {1--6},
doi = {10.25259/gjcsro_7_2026}
}
EUVIMED