EUVIMEDEUVIMED entdecken
Crossref

Observational study to correlate between retinal nerve fibre layer thickness by spectral domain optical coherence tomography and visual field changes in Humphrey field analyser in glaucoma

Deepa Sonawane, Anjali Trivedi, Avani Patel

Global Journal of Cataract Surgery and Research in Ophthalmology · 18.11.2026 · 1-4

DOI: 10.25259/gjcsro_40_2026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Global Journal of Cataract Surgery and Research in Ophthalmology, online erschienen am 18.11.2026. Verfasst von Deepa Sonawane und 2 weiteren Autor:innen. Die Arbeit nennt 6 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The objective of this study was to observe the relationship between retinal nerve fibre layer (RNFL) thickness determined on optical coherence tomography (OCT) and visual field (VF) analysis by Humphrey field analyser in glaucoma patients seen in Dadra and Nagar Haveli. Materials and Methods: This study was performed on 40 eyes of 20 patients with glaucoma. RNFL thickness was measured by Spectral-Domain-OCT and automated perimetry was performed using the 30-2 Swedish interactive thresholding algorithm (SITA) standard strategy Humphrey field analyser. The correlation between RNFL thickness and VF parameters of glaucoma follow-up patients was evaluated.

Results

Mean global RNFL thickness was 46.1 ± 2.6 µm which was significantly correlated with mean deviation (MD) score on automated perimetry (r = 0.64, p = 0.003); significant correlation was observed between VF pattern standard deviation and the corresponding quadrantic RNFL thickness on OCT yet no significant association was found between visual acuity and RNFL thickness.

Conclusion

Mean global RNFL thickness as determined by OCT seems to be correlated with VF defect depth as represented by the MD score on Humphrey VF analyser with worsening glaucoma status of the patients.

Zitieren

APA

Sonawane, D., Trivedi, A., & Patel, A. (2026). Observational study to correlate between retinal nerve fibre layer thickness by spectral domain optical coherence tomography and visual field changes in Humphrey field analyser in glaucoma. Global Journal of Cataract Surgery and Research in Ophthalmology, 0, 1-4. https://doi.org/10.25259/gjcsro_40_2026

Vancouver

Sonawane D, Trivedi A, Patel A. Observational study to correlate between retinal nerve fibre layer thickness by spectral domain optical coherence tomography and visual field changes in Humphrey field analyser in glaucoma. Global Journal of Cataract Surgery and Research in Ophthalmology. 2026;0:1-4. doi:10.25259/gjcsro_40_2026

BibTeX
@article{Sonawane2026,
  author = {Sonawane, Deepa and Trivedi, Anjali and Patel, Avani},
  title = {Observational study to correlate between retinal nerve fibre layer thickness by spectral domain optical coherence tomography and visual field changes in Humphrey field analyser in glaucoma},
  journal = {Global Journal of Cataract Surgery and Research in Ophthalmology},
  year = {2026},
  volume = {0},
  pages = {1--4},
  doi = {10.25259/gjcsro_40_2026}
}
Kostenlos starten →