EUVIMEDEUVIMED entdecken
Crossref

Predictability of arch width changes in patients undergoing extraction versus non-extraction clear aligner therapy: A pilot study

Nihal Kaya, Sabattin Emre Demircan, Merve Zeynep Yavuz, Gokmen Kurt

APOS Trends in Orthodontics · 29.06.2026 · 1-8

DOI: 10.25259/apos_51_2026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift APOS Trends in Orthodontics, online erschienen am 29.06.2026. Verfasst von Nihal Kaya und 3 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to assess the clinical accuracy of digital treatment planning by comparing arch width measurements at pre-treatment (T0), planned with ClinCheck ® software (TC), and achieved at the first refinement stage (T1) in clear aligner (CA)-treated patients with and without extractions. Material and Methods: This retrospective single-center study included 26 patients treated with CAs, divided into non-extraction ( n = 13) and extraction ( n = 13) groups. Arch width measurements were performed in the maxilla at the canine (3–3), second premolar (5–5), and first molar (6–6) regions at T0, TC, and T1. Planned expansion (TC–T0), achieved expansion (T1–T0), and the discrepancy between planned and achieved values (T1–TC) were calculated. Clinical accuracy was expressed as the ratio of achieved to planned expansion. Intra-observer reliability was assessed using the intra-class correlation coefficient (ICC). Statistical analyses were performed using paired t -tests or Wilcoxon tests ( p < 0.05).

Results

Intra-observer reliability was high for all measurements (ICC >0.866). In the non-extraction group, mean planned and achieved expansions were 1.23 mm and 0.94 mm, respectively, corresponding to a clinical accuracy of 66.67%. Significant increases were observed between T0 and T1 at all measurement sites ( p < 0.05). In the extraction group, the mean planned expansion was 1.53 mm, whereas the achieved expansion was limited to 0.34 mm, resulting in a clinical accuracy of 38.92%. Planned expansions were not achieved at any measurement point, and TC–T1 differences were statistically significant ( p < 0.05).

Conclusion

Digital treatment plans with CAs show acceptable clinical accuracy in non-extraction cases, whereas accuracy is substantially reduced in extraction treatments. Therefore, greater caution is required when planning expansion in extraction cases.

Zitieren

APA

Kaya, N., Demircan, S. E., Yavuz, M. Z., & Kurt, G. (2026). Predictability of arch width changes in patients undergoing extraction versus non-extraction clear aligner therapy: A pilot study. APOS Trends in Orthodontics, 0, 1-8. https://doi.org/10.25259/apos_51_2026

Vancouver

Kaya N, Demircan SE, Yavuz MZ, Kurt G. Predictability of arch width changes in patients undergoing extraction versus non-extraction clear aligner therapy: A pilot study. APOS Trends in Orthodontics. 2026;0:1-8. doi:10.25259/apos_51_2026

BibTeX
@article{Kaya2026,
  author = {Kaya, Nihal and Demircan, Sabattin Emre and Yavuz, Merve Zeynep and Kurt, Gokmen},
  title = {Predictability of arch width changes in patients undergoing extraction versus non-extraction clear aligner therapy: A pilot study},
  journal = {APOS Trends in Orthodontics},
  year = {2026},
  volume = {0},
  pages = {1--8},
  doi = {10.25259/apos_51_2026}
}
Kostenlos starten →