Diffusion Weighted Imaging as a Diagnostic Tool in the Evaluation of Ovarian Masses
International Journal of Pharmaceutical Quality Assurance · 16.06.2026 · 17 (06)
DOI: 10.25258/ijpqa.17.6.2 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Pharmaceutical Quality Assurance, online erschienen am 16.06.2026. Verfasst von Ragini T. und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Ovarian masses represent a spectrum of pathologies ranging from benign to malignant lesions. Accurate preoperative differentiation between benign and malignant ovarian masses is crucial for appropriate surgical planning and patient management. Diffusion Weighted Imaging (DWI) is an advanced functional MRI technique that reflects tissue cellularity by measuring the random Brownian motion of water molecules, offering quantitative data through Apparent Diffusion Coefficient (ADC) values.
Objectives
To evaluate the diagnostic accuracy of DWI and ADC values in differentiating benign from malignant ovarian masses, and to determine an optimal ADC cutoff value. Materials and Methods: A retrospective observational study was conducted at the Department of Radiodiagnosis, ACSR Government General Hospital & Government Medical College, Nellore, from January 2023 to June 2025. A total of 30 patients with ovarian masses who underwent plain (non-contrast) MRI pelvis on a 1.5 Tesla Siemens Magnetom Sempra MRI machine were included. DWI was performed and ADC values were calculated. Histopathological findings served as the gold standard.
Results
Of 30 patients, 24 (80%) had benign lesions and 6 (20%) had malignant lesions. DWI restriction was noted in 6 patients, of whom 5 (83.3%) were malignant and 1 (16.7%) was a false positive (endometrioma). One malignant case (low-grade mucinous cystadenocarcinoma) showed no restriction (false negative). The mean ADC value for malignant masses was 0.87 ± 0.18 × 10⁻³ mm²/s versus 1.52 ± 0.43 × 10⁻³ mm²/s for benign masses (p < 0.001). Sensitivity and specificity of DWI were 83.3% and 95.8%, respectively.
Conclusion
DWI combined with ADC value measurement is a valuable, non-invasive, non-contrast adjunct to conventional MRI in characterizing ovarian masses. Combined evaluation significantly improves diagnostic accuracy for ovarian malignancies.
Zitieren
APA
T., R., Kusuma, V., & Lakshmi, G. V. S. (2026). Diffusion Weighted Imaging as a Diagnostic Tool in the Evaluation of Ovarian Masses. International Journal of Pharmaceutical Quality Assurance, 17(06). https://doi.org/10.25258/ijpqa.17.6.2
Vancouver
T. R, Kusuma V, Lakshmi GVS. Diffusion Weighted Imaging as a Diagnostic Tool in the Evaluation of Ovarian Masses. International Journal of Pharmaceutical Quality Assurance. 2026;17(06). doi:10.25258/ijpqa.17.6.2
BibTeX
@article{T2026,
author = {T., Ragini and Kusuma, V. and Lakshmi, G. V. Sunanda},
title = {Diffusion Weighted Imaging as a Diagnostic Tool in the Evaluation of Ovarian Masses},
journal = {International Journal of Pharmaceutical Quality Assurance},
year = {2026},
volume = {17},
number = {06},
doi = {10.25258/ijpqa.17.6.2}
}
EUVIMED