EUVIMEDEUVIMED entdecken
Crossref

Diagnostic Accuracy and Efficacy of FNAC in Thyroid Nodules: A Retrospective Study

Pooja Ranjan, Manisha Liyangi, Budhan Baitha

International Journal of Pharmaceutical Quality Assurance · 30.05.2026 · 17 (05)

DOI: 10.25258/ijpqa.17.5.20 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Pharmaceutical Quality Assurance, online erschienen am 30.05.2026. Verfasst von Pooja Ranjan und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Thyroid nodules are a common clinical entity, with a small but significant proportion of harboring malignancy. Fine needle aspiration cytology (FNAC) has become a key diagnostic tool for early evaluation and risk stratification, particularly in resource-limited settings.

Aim

To assess the diagnostic accuracy and efficacy of FNAC in thyroid nodules by correlating cytological findings with histopathological outcomes. Methodology: This retrospective observational study was conducted on 97 patients with thyroid nodules at Department of Pathology, Phulo Jhano Medical College and Hospital, Dumka, Jharkhand, India. FNAC results were categorized using the Bethesda system and compared with histopathological findings. Diagnostic parameters including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy were calculated.

Results

The study showed a female predominance (78.4%) with a mean age of 41.8 ± 9.6 years. Most cases were benign (49.5%) on FNAC. Sensitivity, specificity, PPV, NPV, and overall diagnostic accuracy of FNAC were 82.5%, 84.2%, 80.5%, 85.9%, and 83.5%, respectively. A progressive increase in malignancy risk was observed with higher Bethesda categories. However, false positives (8 cases) and false negatives (7 cases) were noted.

Conclusion

FNAC is a reliable, minimally invasive, and cost-effective diagnostic modality with good accuracy in evaluating thyroid nodules. However, limitations in indeterminate categories necessitate correlation with histopathology for definitive diagnosis.

Zitieren

APA

Ranjan, P., Liyangi, M., & Baitha, B. (2026). Diagnostic Accuracy and Efficacy of FNAC in Thyroid Nodules: A Retrospective Study. International Journal of Pharmaceutical Quality Assurance, 17(05). https://doi.org/10.25258/ijpqa.17.5.20

Vancouver

Ranjan P, Liyangi M, Baitha B. Diagnostic Accuracy and Efficacy of FNAC in Thyroid Nodules: A Retrospective Study. International Journal of Pharmaceutical Quality Assurance. 2026;17(05). doi:10.25258/ijpqa.17.5.20

BibTeX
@article{Ranjan2026,
  author = {Ranjan, Pooja and Liyangi, Manisha and Baitha, Budhan},
  title = {Diagnostic Accuracy and Efficacy of FNAC in Thyroid Nodules: A Retrospective Study},
  journal = {International Journal of Pharmaceutical Quality Assurance},
  year = {2026},
  volume = {17},
  number = {05},
  doi = {10.25258/ijpqa.17.5.20}
}
Kostenlos starten →