Lubna Naseer, Saadat Nazir Shah, Mahima Sharma

International Journal of Pharmaceutical Quality Assurance · 30.10.2026 · 17 (10)

DOI: 10.25258/ijpqa.17.10.5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Pharmaceutical Quality Assurance, online erschienen am 30.10.2026. Verfasst von Lubna Naseer und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Whole blood collection can occasionally fail even after phlebotomy has been started. Such events result in loss of consumables, staff time and donor effort, and may also affect the donor’s willingness to return. Because these failures often arise from a combination of donor, technical, procedural and environmental factors, we analyzed them using a root cause analysis approach.

Methods

We retrospectively reviewed all whole blood donation attempts recorded over a three-year period in the Department of Transfusion Medicine. Collection failures were classified using the Ishikawa framework under the domains of People, Process, Equipment, Material and Environment. Two investigators reviewed the records independently, and differences were resolved by discussion. Failure rates were compared according to donor sex, collection setting and staff experience. Chi-square or Fisher’s exact test was used as appropriate, and relative risks and odds ratios were calculated with 95% confidence intervals. Pareto analysis was used to identify the main failure modes.

Results

Among 6,021 donation attempts, 85 ended in collection failure, giving an overall failure rate of 1.41%. Failure was more frequent among female donors than male donors, 2.98% versus 1.02%, with a relative risk of 2.92, 95% CI 1.91–4.48. Outdoor camps also had a substantially higher failure rate than in-house collections, 6.87% versus 0.83%, RR 8.31, 95% CI 5.47–12.61. Although outdoor camps accounted for only 9.7% of donation attempts, they contributed 47.1% of all failures. Staff experience was another important factor. Lessexperienced personnel had a higher failure rate than trained personnel, 3.54% versus 0.33%, RR 10.87, 95% CI 6.04–19.58. Among failed collections, phlebotomy-related failures were also more common when lessexperienced staff were involved, 80.6% versus 38.5%, OR 6.63, 95% CI 1.88–23.38. The three most frequent failure modes were hematoma, vasovagal reaction and clot formation, which together accounted for 83.5% of all failures.

Conclusion

Collection failure was uncommon, but it showed a consistent pattern. Most failures were related to the phlebotomy process and were associated with staff experience and outdoor camp conditions. The findings support a CAPA plan focused on competency-based training, closer supervision, better management of difficult venous access, early correction of slow flow, and prevention of vasovagal reactions and standardization of outdoor camp practices. These measures should be evaluated prospectively.

Zitieren

APA

Naseer, L., Shah, S. N., & Sharma, M. (2026). From Failure Modes to Modifiable Factors: Root Cause Analysis of Whole Blood Collection Failure. International Journal of Pharmaceutical Quality Assurance, 17(10). https://doi.org/10.25258/ijpqa.17.10.5

Vancouver

Naseer L, Shah SN, Sharma M. From Failure Modes to Modifiable Factors: Root Cause Analysis of Whole Blood Collection Failure. International Journal of Pharmaceutical Quality Assurance. 2026;17(10). doi:10.25258/ijpqa.17.10.5

BibTeX
@article{Naseer2026,
  author = {Naseer, Lubna and Shah, Saadat Nazir and Sharma, Mahima},
  title = {From Failure Modes to Modifiable Factors: Root Cause Analysis of Whole Blood Collection Failure},
  journal = {International Journal of Pharmaceutical Quality Assurance},
  year = {2026},
  volume = {17},
  number = {10},
  doi = {10.25258/ijpqa.17.10.5}
}
Kostenlos starten →