A Cross-Sectional Clinical Study to Evaluate the Correlation Between Intraocular Pressure and Central Corneal Thickness in Glaucoma Suspects

Maninee Suman, Kunal Kumar, Nandani Priyadarshini

International Journal of Pharmaceutical Quality Assurance · 09.07.2026 · 16 (09)

DOI: 10.25258/ijpqa.16.9.90 ↗

Kurz gefasst

Querschnittstudie in der Zeitschrift International Journal of Pharmaceutical Quality Assurance, online erschienen am 09.07.2026. Verfasst von Maninee Suman und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Glaucoma is one of the leading causes of irreversible blindness and islargely affected by intraocular pressure (IOP). Central corneal thickness (CCT) is also used to estimate IOP. Accurate measurement of CCT and its correlation with IOP is important for proper diagnosis and management of glaucoma suspect patients.

Aim

To determine the correlation between IOP and CCT in glaucoma suspects and patients at risk for developing glaucoma.

Methods

Eighty patients older than 40 years who attended the Ophthalmology Department and had IOP measured with Goldmann Applanation Tonometry and CCT recorded by Pachymetry were included in this crosssectional clinical study. A standardized linear correction factor corrected IOP values and statistical analysis of data utilized Pearson Correlation Coefficient t-test, ANOVA.

Results

There was a statistically significant difference (p < 0.0001) between the average IOP and thickness of corneas across the POAG (mean ± SD: 25.28 mmHg ± 6.52, 548.1 µm ± 72.94), PACG (mean ± SD: 23.2 mmHg ± 8.6, 558.9 µm ± 75.25), OHT (mean ± SD: 25.6 mmHg ± 5.42, 566.4 µm ± 74.65), and suspect glaucoma groups (mean ± SD: 20.75 mmHg ± 5.29, 556.2 µm ± 79.03). The highest IOP at 28.15 mmHg is seen in those with thin corneas (< 540 µm) and the lowest at 23.48 mmHg in normal thickness corneas (540–580 mm) and higher at 24.6 mmHg in thick corneas (>580 mm), indicating a statistically significant relationship between CCT and IOP.

Conclusion

In glaucoma suspects, thinner corneas correlate with higher corrected IOP values, while thicker corneas often produce IOP overestimation. Taking CCT into account increases the accuracy of diagnosing glaucoma suspects and is helpful for assigning them risk stratification.

Zitieren

APA

Suman, M., Kumar, K., & Priyadarshini, N. (2026). A Cross-Sectional Clinical Study to Evaluate the Correlation Between Intraocular Pressure and Central Corneal Thickness in Glaucoma Suspects. International Journal of Pharmaceutical Quality Assurance, 16(09). https://doi.org/10.25258/ijpqa.16.9.90

Vancouver

Suman M, Kumar K, Priyadarshini N. A Cross-Sectional Clinical Study to Evaluate the Correlation Between Intraocular Pressure and Central Corneal Thickness in Glaucoma Suspects. International Journal of Pharmaceutical Quality Assurance. 2026;16(09). doi:10.25258/ijpqa.16.9.90

BibTeX
@article{Suman2026,
  author = {Suman, Maninee and Kumar, Kunal and Priyadarshini, Nandani},
  title = {A Cross-Sectional Clinical Study to Evaluate the Correlation Between Intraocular Pressure and Central Corneal Thickness in Glaucoma Suspects},
  journal = {International Journal of Pharmaceutical Quality Assurance},
  year = {2026},
  volume = {16},
  number = {09},
  doi = {10.25258/ijpqa.16.9.90}
}
Kostenlos starten →